Prospective Durability Testing of a Vascular Access Phantom
Authors:
Open Access
- 1 September 2010
- journal article
- Vol. 11 (4) , 302-305
Abstract
We assessed the acoustic transmission, image quality, and vessel integrity of the Blue Phantom™ 2 Vessel Original Ultrasound Training Model with repeated use. The study consisted of two phases. During the first phase, a portion of the Blue Phantom™ rubber matrix (without a simulated vessel) was placed over a two-tiered echogenic structure and was repeatedly punctured with a hollow bore 18-gauge needle in a 1 cm2 area. During the second phase, a portion of the matrix with a simulated vessel was repeatedly punctured with another hollow bore 18-gauge needle. During both phases we obtained an ultrasound image using a high-frequency linear probe after every 100 needle punctures to assess the effect of repeated needle punctures on image quality, acoustic transmission, and simulated vessel integrity. Testing on the rubber matrix alone (first phase) without a vessel demonstrated a gradual decrease in image quality and visualization of the proximal and distal portions of the target structure, but they remained visible after 1,000 needle punctures. The second phase demonstrated excellent acoustic transmission and image quality on both transverse and longitudinal images of the rubber matrix and simulated vessel after 1,000 needle punctures. The anterior and posterior vessel walls and needle tip were well visualized without any signs of vessel leakage on still images or with compression and power Doppler. The Blue Phantom™ 2 Vessel Original Ultrasound Training Model demonstrated excellent durability after 1,000 needle punctures in a 1- cm2 area. Based on the length of simulated vessel in each model, it should support over 25,000 simulated attempts at vascular access.Keywords
This publication has 17 references indexed in Scilit:
- Ultrasound averts inadvertent injury during internal jugular vein cannulationCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2008
- Ultrasound-Assisted Peripheral Venous Access in Young Children: A Randomized Controlled Trial and Pilot Feasibility Study2008
- Ultrasonography-Guided Peripheral Intravenous Access Versus Traditional Approaches in Patients With Difficult Intravenous AccessAnnals of Emergency Medicine, 2005
- Emergency Nurses' Utilization of Ultrasound Guidance for Placement of Peripheral Intravenous Lines in Difficult‐access PatientsAcademic Emergency Medicine, 2004
- Ultrasound-Guided Brachial and Basilic Vein Cannulation in Emergency Department Patients With Difficult Intravenous AccessAnnals of Emergency Medicine, 1999
- Sonographic guidance when using the right internal jugular vein for central vein access.American Journal of Roentgenology, 1998
- Cannulation of the internal jugular vein: comparison of the classic Seldinger technique and an ultrasound guided method.1998
- Real-Time Ultrasound–Guided Femoral Vein Catheterization During Cardiopulmonary ResuscitationAnnals of Emergency Medicine, 1997
- Real-time ultrasound guided internal jugular vein catheterization in the emergency departmentThe American Journal of Emergency Medicine, 1997
- Uncomplicated Central Vein Catheterization of High Risk Patients with Real Time Ultrasound GuidanceThe International Journal of Artificial Organs, 1995