The ‘critical trochanter angle’: a predictor for stem alignment in total hip arthroplasty
Open Access
- 30 May 2019
- journal article
- research article
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 165
Abstract
Stem malalignment can affect offset reconstruction and may result in gluteal muscle insufficiency. In this retrospective study, a novel geometric angle named ‘critical trochanter angle’ (CTA) is described and investigated towards the risk of malposition of a collarless straight tapered hydroxyapatite-coated stem in primary total hip arthroplasty (THA). A total of 100 cementless THA were implanted in patients with unilateral coxarthrosis via the direct anterior (n = 50) or direct lateral Hardinge approach (n = 50) in a two surgeon setting using the Corail® or Trendhip® stem (DePuy Synthes or Aesculap). Stem alignment was analysed in postoperative AP pelvic radiographs and correlated to the CTA: the angle crest was defined by the intersection of the femoral shaft and neck axis and the angle was measured between the shaft axis and a leg intersecting the vertex between the lateral and superoposterior facet of the trochanter. Forty-seven stems were implanted in varus (≥ + 1°), 42 in neutral (< + 1°/> − 1°) and 11 in valgus position (≤ − 1°). The mean critical trochanter angle was 25.0° (SD ± 7.5°), and there was a negative and statistically significant correlation to stem alignment (r = − 0.52; p ≤ 0.001) independent from the surgical approach. For stem malposition of 2° and above (n = 23), mean CTA was 17.2° for varus (n = 20) and 31.6° for valgus (n = 3). A CTA lesser or equal to 22.75° had a sensitivity of 90% and specificity of 80% for varus stem position of 2° or greater. Specificity raised to 100% with a cutoff CTA of 12.5° or lesser. Varus stem alignment in THA is associated with coxa vara deformity and a radiological low CTA. In preoperative planning, the critical trochanter angle can help to evaluate the risk for intraoperative stem malpositioning. If navigation or robotic assistance is not available when using this stem design, we recommend an intraoperative x-ray to verify correct implant positioning in patients with a CTA under 20° or above 30°.Keywords
This publication has 16 references indexed in Scilit:
- Does hydroxyapatite coating of uncemented cups improve long-term survival? An analysis of 28,605 primary total hip arthroplasty procedures from the Nordic Arthroplasty Register Association (NARA)Osteoarthritis and Cartilage, 2017
- Long-term survivorship of the Corail™ standard stemOrthopaedics & Traumatology: Surgery & Research, 2017
- Varus will Have Varus; A Radiological Study to Assess and Predict Varus Stem Placement in Uncemented Femoral StemsHIP International, 2016
- Long-term Bone Remodeling in HA-coated Stems: A Radiographic Review of 208 Total Hip Arthroplasties (THAs) with 15 to 20 Years Follow-up.2015
- The role of femoral offset and abductor lever arm in total hip arthroplastyJournal of Orthopaedics and Traumatology, 2015
- Hydroxyapatite coating does not improve uncemented stem survival after total hip arthroplasty!Acta Orthopaedica, 2014
- Performance of the CLS Spotorno uncemented stem in the third decade after implantationThe Bone & Joint Journal, 2014
- Direct Anterior Approach for Total Hip ArthroplastyOrthopedic Clinics of North America, 2009
- Hydroxyapatite-Coated Tapered Cementless Femoral Components in Total Hip ArthroplastyThe Journal of Arthroplasty, 2007
- Osseointegration in hip prostheses: experimental study in sheepInternational Orthopaedics, 2003