Early Detection and Quantitative Analysis of Skin Cancer Using THz Metamaterial Biosensor
Authors:
- Universiti Tun Hussein Onn MalaysiaUMUniversiti Tun Hussein Onn Malaysia
- Suhail Asghar QureshiSuhail Asghar Qureshi
- Zuhairiah Zainal AbidinZAZuhairiah Zainal Abidin
- Muhammad Ramlee KamarudinMKMuhammad Ramlee Kamarudin
- Nurul Bashirah GhazaliNGNurul Bashirah Ghazali
- Kuala Lumpur EvisKEKuala Lumpur Evis
- 12 August 2024
- journal article
- research article
- Published by Penerbit UTHM in International Journal of Integrated Engineering
- Vol. 16 (5) , 275-282
Abstract
Terahertz imaging offers significant potential for the early detection of skin cancer. This study introduces a metamaterial unit cell designed to operate in the terahertz (THz) band for non-invasive contact-based skin cancer detection. The sensor relies exclusively on the reflection coefficient response, providing high sensitivity to subtle changes in tissue properties without requiring complex signal processing. This simplicity may result in a cost-effective and straightforward implementation for early cancer detection.Simulations were conducted using 3D models representing various skin types, including normal skin, basal cell carcinoma (BCC), and melanoma. The dielectric characteristics of the samples were determined using the Double Debye model. The simulations revealed that the metamaterial design exhibited double negative material properties at a specific frequency of 1.15 THz. Upon skin contact and detection of malignancy, the reflection coefficient showed a shift toward lower frequencies. Notably, the melanoma sample exhibited the most significant shift, indicating a more severe form of cancer compared to BCC. Furthermore, it was observed that the difference in resonance frequencies between normal and malignant skin increased with the thickness of the sample. The sensor demonstrated high sensitivity in detecting cancer thickness, with a sensitivity of 9.25 GHz/μm for basal cell carcinoma (BCC) and 10.2 GHz/μm for melanoma. Furthermore, linear regression analysis revealed a robust correlation between the resonance frequency and the variation in cancer thickness, with R2 values of 0.9948 and 0.9947 for BCC and melanoma, respectively. These findings underscore the sensor's ability to detect skin cancer at its earliest stages, regardless of its severity.Keywords
This publication has 22 references indexed in Scilit:
- Multiplexed Hybrid Plasmonic Ring Resonator Sensor for Label Free Biosensing ApplicationsSensing and Imaging, 2023
- Vivaldi antenna for early cancer detection based on THz spectroscopy: Comparison between response of breast and skin cancerOptik, 2022
- Developing THz metasurface with array rectangular slot with High Q-factor for early skin cancer detectionOptik, 2022
- Design of optical antenna operating at Terahertz frequency for In-Vivo cancer detectionOptik, 2020
- Broadband terahertz reconfigurable metasurface based on 1-bit asymmetric coding metamaterialOptics Communications, 2020
- Number of skin biopsies needed per malignancy: Comparing the use of skin biopsies among dermatologists and nondermatologist cliniciansJournal of the American Academy of Dermatology, 2020
- Ovarian cancer: Current status and strategies for improving therapeutic outcomesCancer Medicine, 2019
- Dielectric and Double Debye Parameters of Artificial Normal Skin and MelanomaJournal of Infrared, Millimeter, and Terahertz Waves, 2019
- Terahertz biosensing with a graphene-metamaterial heterostructure platformCarbon, 2019
- Early skin cancer detection sensor based on photonic band gap and graphene load at terahertz regimeOptical and Quantum Electronics, 2018