Near midplane scintillator-based fast ion loss detector on DIII-D

Authors:

Abstract
A new scintillator-based fast-ion loss detector (FILD) installed near the outer midplane of the plasma has been commissioned on DIII-D. This detector successfully measures coherent fast ion losses produced by fast-ion driven instabilities (≤500 kHz). Combined with the first FILD at ∼45° below the outer midplane [R. K. Fisher, et al., Rev. Sci. Instrum. 81, 10D307 (2010)], the two-detector system measures poloidal variation of losses. The phase space sensitivity of the new detector (gyroradius rL ∼ [1.5–8] cm and pitch angle α ∼ [35°–85°]) is calibrated using neutral beam first orbit loss measurements. Since fast ion losses are localized poloidally, having two FILDs at different poloidal locations allows for the study of losses over a wider range of plasma shapes and types of loss orbits.
Funding Information
  • U.S. Department of Energy (DE-FC02-04ER54698, DE-FG03-94ER54271, SC-G903402)

This publication has 12 references indexed in Scilit: