Robust H∞ glucose control in diabetes using a physiological model
Authors:
- 1 December 2000
- journal article
- research article
- Published by Wiley in AIChE Journal
- Vol. 46 (12) , 2537-2549
Abstract
A robust H∞ controller was developed to deliver insulin via a mechanical pump in Type I diabetic patients. A fundamental nonlinear diabetic patient model was linearized and then reduced to a third‐order linear form for controller synthesis. Uncertainty in the nonlinear model was characterized by up to ±40% variation in eight physiological parameters. A sensitivity analysis identified the three‐parameter set having the most significant effect on glucose and insulin dynamics over the frequency range of interest ω = [0.002, 0.2] (rad/min). This uncertainty was represented in the frequency domain and incorporated in the controller design. Controller performance was assessed in terms of its ability to track a normoglycemic set point (81.1 mg/dL) in response to a 50 g meal disturbance. In the nominal continuous‐time case, the controller maintained glucose concentrations within ±3.3 mg/dL of set point. A controller tuned to accommodate uncertainty yielded a maximum deviation of 17.6 mg/dL for the worst‐case parameter variation.Keywords
This publication has 21 references indexed in Scilit:
- Repeatability of Insulin Sensitivity and Glucose Effectiveness From the Minimal Model: Implications for Study DesignDiabetes, 1994
- On line continuous monitoring of subcutaneous tissue glucose in men by combining portable glucosensor with microdialysisDiabetologia, 1992
- A physiological model of glucose-insulin interaction in type 1 diabetes mellitusJournal of Biomedical Engineering, 1992
- Application of optimal control theory to diabetes mellitusInternational Journal of Control, 1989
- State-space solutions to standard H/sub 2/ and H/sub infinity / control problemsIEEE Transactions on Automatic Control, 1989
- All optimal Hankel-norm approximations of linear multivariable systems and theirL,∞-error bounds†International Journal of Control, 1984
- Validation of mathematical models of complex endocrine-metabolic systems. A case study on a model of glucose regulationMedical & Biological Engineering & Computing, 1983
- Physiologic evaluation of factors controlling glucose tolerance in man: measurement of insulin sensitivity and beta-cell glucose sensitivity from the response to intravenous glucose.Journal of Clinical Investigation, 1981
- Principal component analysis in linear systems: Controllability, observability, and model reductionIEEE Transactions on Automatic Control, 1981
- Model studies of blood-glucose regulationBulletin of Mathematical Biology, 1965