Comparative Pull-Out Strength of Tapped and Untapped Pilot Holes for Bicortical Anterior Cervical Screws
- 15 January 1997
- journal article
- biomechanic
- Published by Wolters Kluwer Health in Spine
- Vol. 22 (2) , 167-170
Abstract
Study Design This biomechanical study analyzed the axial pull-out strength of tapped versus untapped pilot holes for bicortical screws in the anterior cervical spine. Objective To determine which pilot hole preparation method was mechanically better. Summary of Background Data Tapping pilot holes in the lumbar spine was previously shown significantly to reduce pull-out strength of pedicle screws. No study was found investigating the effect of tapping on pilot holes for anterior cervical bicortical screws. Methods Twenty-five unembalmed human cadaveric cervical vertebrae (C3-C7) were tested. Two identical pilot holes were drilled into each vertebra: one pilot hole was tapped, and the control pilot hole was not tapped. A fully threaded cortical bone screw was inserted into each pilot hole. Screw pull-out strength was determined using a servocontrolled hydraulic materials testing system and an axial load cell. Force-deformation and failure curves were obtained. Results There were no statistically significant differences between the axial pull-out strength of tapped and untapped pilot holes at any vertebral level. Mean force-to-failure was 386 ± 42 N in the untapped pilot holes and 397 ± 48 N in the tapped pilot holes. Conclusions Tapping a pilot hole for bicortical screws of the anterior cervical spine neither weakens nor strengthens the axial pull-out strength of fully threaded cortical bone screws. Tapping may be unnecessary; however, it may be desirable in patients with dense bone to cut the thread profile into the bone or if the screws have dull tips and threads.Keywords
This publication has 11 references indexed in Scilit:
- Assessment of Unicortical and Bicortical Fixation in a Quasistatic Cadaveric ModelSpine, 1995
- Biomechanical analysis of bone mineral density, insertion technique, screw torque, and holding strength of anterior cervical plate screwsJournal of Neurosurgery, 1995
- Biomechanical Evaluation of Caspar Cervical ScrewsNeurosurgery, 1993
- Pullout Strength Comparison of Two Methods of Orienting Screw Insertion in the Lateral Masses of the Bovine Cervical SpineJournal of Spinal Disorders, 1992
- Pull-out Strength of Caspar Cervical ScrewsNeurosurgery, 1992
- Pitfalls of Biomechanical TestingSpine, 1991
- Biomechanics of Thoracolumbar Spinal FixationSpine, 1991
- Biomechanical Evaluation of Cervical Spinal Stabilization Methods in a Human Cadaveric ModelSpine, 1989
- The Effect of Movement on the Holding Power of Screws in BoneClinical Orthopaedics and Related Research, 1975
- The Holding Power of Orthopedic Screws In VivoClinical Orthopaedics and Related Research, 1975