An FBG‐based optical pressure sensor for the measurement of radial artery pulse pressure
- 2 May 2024
- journal article
- research article
- Published by Wiley in Journal of Biophotonics
- Vol. 17 (7) , e202400083
Abstract
One of the diagnostic tool for clinical evaluation and disease diagnosis is a pulse waveform analysis. High fidelity radial artery pulse waveforms have been investigated in clinical research to compute central aortic pressure, which has been demonstrated to be predictive of cardiovascular diseases. The radial artery must be inspected from several angles in order to obtain the best pulse waveform for estimate and diagnosis. In this study, we present the design and experimental testing of an optical sensor based on Fiber Bragg Gratings (FBG). A 3D printed device along with the FBG is used to measure the radial artery pulses. The proposed sensor is used for the purpose of quantifying the radial artery pulse waveform across major pulse position point. The suggested optical sensing system can measure the pulse signal with good accuracy. The main characteristic parameters of the pulse can then be retrieved from the processed signal for their use in clinical applications. By conducting experiments under the direction of medical experts, the pulse signals are measured. In order to experimentally validate the sensor, we used it to detect the pulse waveforms at Guan position of the wrist's radial artery in accordance with the diagnostic standards. The findings show that combining optical technologies for physiological monitoring and radial artery pulse waveform monitoring using FBG in clinical applications are highly feasible.Keywords
This publication has 54 references indexed in Scilit:
- An Efficient Low Power MEMS-Based Microfluidic Device for the Segregation of Different Blood Components2021
- A High-Precision and Miniature Fiber Bragg Grating-Based Force Sensor for Tissue Palpation During Minimally Invasive SurgeryAnnals of Biomedical Engineering, 2019
- Development of a 6-DoF FBG force–moment sensor for a haptic interface with minimally invasive robotic surgeryJournal of Mechanical Science and Technology, 2016
- Fiber bragg grating sensor based device for simultaneous measurement of respiratory and cardiac activitiesJournal of Biophotonics, 2016
- Highly Skin‐Conformal Microhairy Sensor for Pulse Signal AmplificationAdvanced Materials, 2014
- How to standardize the pulse-taking method of traditional Chinese medicine pulse diagnosisComputers in Biology and Medicine, 2013
- Possibility of quantifying TCM finger-reading sensations: I. Bi-Sensing Pulse Diagnosis InstrumentEuropean Journal of Integrative Medicine, 2012
- Computational methods for Traditional Chinese Medicine: A surveyComputer Methods and Programs in Biomedicine, 2007
- Developing classification indices for Chinese pulse diagnosisComplementary Therapies in Medicine, 2007
- Percutaneous radial artery approach for coronary angiographyCatheterization and Cardiovascular Diagnosis, 1989