Background and purpose: Soong classification is used to estimate volar locking plate prominence and evaluate the risk for flexor tendon ruptures after surgical treatment of distal radius fractures (DRFs). However, the scientific community has questioned the Soong classification due to lacking evidence. Therefore, this study aimed to evaluate the accuracy of Soong grading as a predictor for flexor tendon issues and plate removal. Patients and methods: We performed a retrospective single-center review of adult distal radius fracture patients treated with a volar locking plate between 2009 and 2019. In total, 2779 patients were included in the study. The primary outcome was a flexor tendon issue (flexor tendon rupture, tendinitis, or flexor irritation), whereas plate removal was a secondary outcome. Using Soong grade 0 as a reference, we used univariable and multivariable logistic regression to calculate odds ratios (OR) with 95% confidence intervals (CI) for flexor tendon issues and plate removal. Results: In total, 756 (27%) patients were graded as Soong 0, 1679 (60%) Soong 1, and 344 (12%) Soong 2, respectively. There were 32 (1.2%) patients with flexor tendon issues, of which 4 were flexor tendon ruptures, 8 tendinitises, and 20 flexor irritations. The adjusted OR for flexor tendon issues was 4.4 (CI 1.1–39.7) for Soong grade 1 and 9.7 (CI 2.2–91.1) for Soong grade 2. The plate was removed from 167 (6.0%) patients. Soong grade 1 had a univariable OR of 1.8 (CI 1.2–2.8) for plate removal, and Soong grade 2 had an OR of 3.5. (CI 2.1–5.8), respectively. Conclusion: Flexor tendon ruptures are rare complications after the volar plating of DRFs. A higher Soong grade is a risk factor for flexor tendon issues and plate removal. Trial registration: The trial was retrospectively registered.Keywords
Funding Information
- Paulon Säätiö
- University of Helsinki including Helsinki University Central Hospital
This publication has 25 references indexed in Scilit:
- Reliability of the Soong Classification for Volar Plate PositionThe Journal of Hand Surgery, 2016
- Incidence of Hardware Removal Following Volar Plate Fixation of Distal Radius FractureThe Journal of Hand Surgery, 2015
- Are Volar Locking Plates Superior to Percutaneous K-wires for Distal Radius Fractures? A Meta-analysisClinical Orthopaedics and Related Research, 2015
- Incidence and Reasons for Hardware Removal Following Operative Fixation of Distal Radius FracturesThe Journal of Hand Surgery, 2015
- Volar Plate Position and Flexor Tendon Rupture Following Distal Radius Fracture FixationThe Journal of Hand Surgery, 2013
- Incidence and Clinical Outcomes of Tendon Rupture Following Distal Radius FractureThe Journal of Hand Surgery, 2012
- Significant Change in the Surgical Treatment of Distal Radius Fractures: A Nationwide Study Between 1998 and 2008 in FinlandJournal of Trauma: Injury, Infection & Critical Care, 2011
- Volar Locking Plate Implant Prominence and Flexor Tendon RuptureJournal of Bone and Joint Surgery, 2011
- Flexor Pollicis Longus Tendon Ruptures after Palmar Plate Fixation of Fractures of the Distal RadiusJournal of Hand Surgery (European Volume), 2009
- Reducing bias through directed acyclic graphsBMC Medical Research Methodology, 2008