Electrical machines fault diagnosis by stray flux analysis
Authors:
- 1 March 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 247-256
Abstract
The stray flux in the vicinity of an electrical machine is inherent to its running. It is tied to the magnetic state of the machine and therefore can be affected by the presence of a fault in the machine. Accurate modeling of the external magnetic field is quite complicated and simple models are required in order to analyze the effect of an internal fault on the stray flux. This paper displays the possibilities offers by the stray flux for fault detection. A simple model of the external magnetic field is presented and a study in healthy and faulty conditions is developed. Two kind of fault in induction machine are considered: stator inter-turn short-circuit and rotor broken bar. Experimental results are in agreement with the theory, they highlight the differentiation between the radial flux and the axial flux.Keywords
This publication has 38 references indexed in Scilit:
- Detection of eccentricity and bearings fault using stray flux monitoring2011
- Discriminating the Simultaneous Occurrence of Three-Phase Induction Motor Rotor Faults and Mechanical Load Oscillations by the Instantaneous Active and Reactive Power Media Signature AnalysesIEEE Transactions on Industrial Electronics, 2011
- Fault Diagnosis in Industrial Induction Machines Through Discrete Wavelet TransformIEEE Transactions on Industrial Electronics, 2010
- Diagnosis of Induction Motor Faults in Time-Varying Conditions Using the Polynomial-Phase Transform of the CurrentIEEE Transactions on Industrial Electronics, 2010
- Detection of Broken Bars in Induction Motor Through the Analysis of Supply Voltage ModulationIEEE Transactions on Industrial Electronics, 2009
- Instantaneous Frequency of the Left Sideband Harmonic During the Start-Up Transient: A New Method for Diagnosis of Broken BarsIEEE Transactions on Industrial Electronics, 2009
- Advances in Diagnostic Techniques for Induction MachinesIEEE Transactions on Industrial Electronics, 2008
- On the stray flux analysis for the detection of the three-phase induction machine faults2005
- Detection and location of interturn short circuits in the stator windings of operating motorsIEEE Transactions on Energy Conversion, 1994
- Contribution to the study of leakage fields at the ends of rotating electrical machinesProceedings of the Institution of Electrical Engineers, 1978