Airborne Measurements of CO2 Column Concentration and Range Using a Pulsed Direct-Detection IPDA Lidar
Open Access
- 30 December 2013
- journal article
- research article
- Published by MDPI AG in Remote Sensing
- Vol. 6 (1) , 443-469
Abstract
We have previously demonstrated a pulsed direct detection IPDA lidar to measure range and the column concentration of atmospheric CO2. The lidar measures the atmospheric backscatter profiles and samples the shape of the 1,572.33 nm CO2 absorption line. We participated in the ASCENDS science flights on the NASA DC-8 aircraft during August 2011 and report here lidar measurements made on four flights over a variety of surface and cloud conditions near the US. These included over a stratus cloud deck over the Pacific Ocean, to a dry lake bed surrounded by mountains in Nevada, to a desert area with a coal-fired power plant, and from the Rocky Mountains to Iowa, with segments with both cumulus and cirrus clouds. Most flights were to altitudes >12 km and had 5–6 altitude steps. Analyses show the retrievals of lidar range, CO2 column absorption, and CO2 mixing ratio worked well when measuring over topography with rapidly changing height and reflectivity, through thin clouds, between cumulus clouds, and to stratus cloud tops. The retrievals shows the decrease in column CO2 due to growing vegetation when flying over Iowa cropland as well as a sudden increase in CO2 concentration near a coal-fired power plant. For regions where the CO2 concentration was relatively constant, the measured CO2 absorption lineshape (averaged for 50 s) matched the predicted shapes to better than 1% RMS error. For 10 s averaging, the scatter in the retrievals was typically 2–3 ppm and was limited by the received signal photon count. Retrievals were made using atmospheric parameters from both an atmospheric model and from in situ temperature and pressure from the aircraft. The retrievals had no free parameters and did not use empirical adjustments, and >70% of the measurements passed screening and were used in analysis. The differences between the lidar-measured retrievals and in situ measured average CO2 column concentrations were 6 km.Keywords
This publication has 30 references indexed in Scilit:
- Atmospheric CO2 column measurements with an airborne intensity-modulated continuous wave 157 μm fiber laser lidarApplied Optics, 2013
- Retrieval algorithm for CO2 and CH4 column abundances from short-wavelength infrared spectral observations by the Greenhouse gases observing satelliteAtmospheric Measurement Techniques, 2011
- Pulsed airborne lidar measurements of atmospheric CO2 column absorptionTellus B: Chemical and Physical Meteorology, 2010
- Space-borne remote sensing of CO2, CH4, and N2O by integrated path differential absorption lidar: a sensitivity analysisApplied Physics B, 2008
- A laser sounder for measuring atmospheric trace gases from space2007
- Uncertainties in the space-based measurements of CO2 columns due to scattering in the Earth's atmosphereJournal of Quantitative Spectroscopy and Radiative Transfer, 2007
- Global observations of the carbon budget, 2, CO2 column from differential absorption of reflected sunlight in the 1.61 μm band of CO2Journal of Geophysical Research: Atmospheres, 2002
- Spaceborne measurements of atmospheric CO2 by high‐resolution NIR spectrometry of reflected sunlight: An introductory studyGeophysical Research Letters, 2002
- A Large Terrestrial Carbon Sink in North America Implied by Atmospheric and Oceanic Carbon Dioxide Data and ModelsScience, 1998
- Observational Contrains on the Global Atmospheric Co 2 BudgetScience, 1990