Optimization and characterization of a lactate-oxidase electrode
Authors:
Open Access
- 31 October 2025
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 15 (50) , 42533-42544
Abstract
Electrochemical lactate sensors, used for analyzing biological fluids such as blood, sweat, and saliva, are gaining significant interest in healthcare and sports fields. A pivotal element that affects these sensors' performance is the lactate oxidase-based electrode. This study focused on enhancing the performance of the lactate oxidase electrode by optimizing the loading and layering of lactate oxidase (LOx) and poly(ethylene glycol) diglycidyl ether (PEGDGE) on carbon paper via the Box–Behnken design. The electrode surface was characterized utilizing FE-SEM, FTIR, and impedance analyses, with performance evaluation conducted via electrochemical and biochemical analyses. The optimized electrode, incorporating four layers of LOx (1.9 U) and PEGDGE (184 μg), generated an oxidation current of 1840 ± 60 μA, displaying high enzyme activity. It exhibited a maximum current at a lactate concentration of 50 mM, an apparent Kapp m of 11.4 mM, and high stability with robust enzyme binding, thus supporting repeated use across numerous cycles. These results are instrumental in advancing the development of more effective and dependable lactate biosensors.Keywords
Funding Information
- National Research Foundation of Korea
- Ministry of Science and ICT, South Korea (NRF-2020R1F1A1054433)
- Ministry of Education (2025-RISE-16-001)
This publication has 50 references indexed in Scilit:
- Redox Behaviour and Redox Potentials of Dyes in Aqueous Buffers and Protic Ionic LiquidsChemistry – A European Journal, 2024
- Response surface optimization and finite element homogenization study of the effective elastic modulus and electrical conductivity of MXene‐polypyrrole hybrid nanocomposite as electrode material for electronic energy storage devicesPolymer Engineering & Science, 2022
- Response surface methodology for microwave-assisted extraction of pectin from cocoa pod husk (Theobroma cacao) mediated by oxalic acidJournal of Food Measurement and Characterization, 2020
- Fabrication of optimally configured layers of SWCNTs, gold nanoparticles, and glucose oxidase on ITO electrodes for high-power enzymatic biofuel cellsKorean Journal of Chemical Engineering, 2019
- Preparation of a Poly(ethylene glycol)‐Based Cross‐Linked Network from a Click Reaction for Enzyme ImmobilizationChemistrySelect, 2019
- Optimization and characterization of covalent immobilization of glucose oxidase for bioelectronic devicesBiochemical Engineering Journal, 2016
- An L‐Lactate Amperometric Enzyme Electrode Based on L‐Lactate Oxidase Immobilized in a Laponite Gel on a Glassy Carbon Electrode. Application to Dairy Products and Red WineElectroanalysis, 2010
- Box-Behnken design: An alternative for the optimization of analytical methodsAnalytica Chimica Acta, 2007
- Multilayer membranes for glucose biosensing via layer-by-layer assembly of multiwall carbon nanotubes and glucose oxidaseAnalytical Biochemistry, 2006
- Electrochemical bioreactor with regeneration of NAD+ by rotating graphite disk electrode with PMS adsorbedEnzyme and Microbial Technology, 1992