Use of robot technology in passive mobilization of acute hospitalized geriatric medicine patients: a pilot test and feasibility study
Top Cited Papers
Open Access
- 6 January 2020
- journal article
- research article
- Published by Springer Nature in Pilot and Feasibility Studies
- Vol. 6 (1) , 1-9
Abstract
Background: Along with an aging population, the field of robot technology in rehabilitation is expanding. As new technologies develop, it is important to test these clinically before implementation. To assess the possibilities of undertaking a future randomized controlled trial (RCT), the aim of this study was to pilot test and investigate the feasibility of a newly developed passive mobilization robot device in geriatric medicine patients. Methods: We used a robot to perform passive mobilization for all recruited patients while they were lying in bed. Inclusion criteria include the following: ≥ 65 years of age, able to walk before hospitalization, and not capable of walking > 2 m at the first day of hospitalization. Exclusion criteria include the following: known moderate/severe dementia, unstable fractures (back, pelvis, or legs), high intracranial pressure, pressure ulcers/risk of developing pressure ulcers due to fragile skin, positive Confusion and Assessment Method (CAM) score, not able to understand Danish, and medical instability. A mixed-methods approach, including structured interviews for patients and relatives, questionnaires and semi-structured interviews for the staff, and observations in the clinic were used as data collection methods. A 6-week pilot test preceded the feasibility study to test study design, safety, interview guide, and setting, and to become familiar with the robot. Results: The pilot test included 13 patients, made the staff confident in the use of the robot, and led to the correction of the interview guide. In the feasibility study, 177 patients were screened, 14 patients (four men, nine women) included, and 13 completed the intervention (median [IQR] age 86 [82–92] years). Overall, the robot was easy to use during passive mobilization and fully accepted by patients and relatives. Staff, however, found the robot difficult to maneuver. No adverse events were reported. Conclusions: Use of robot technology in passive mobilization of older patients was feasible and well accepted by patients, relatives, and staff. Technical and workflow-related issues, as well as the robot not performing active mobilization, affects the launch of a RCT and thereby its implementation in geriatric medicine patients.Keywords
Funding Information
- Markedsmodningsfonden
- Life Science Robotics ApS, DK (none)
This publication has 27 references indexed in Scilit:
- Twenty-Four-Hour Mobility During Acute Hospitalization in Older Medical PatientsThe Journals of Gerontology, Series A: Biological Sciences and Medical Sciences, 2012
- Low Mobility During Hospitalization and Functional Decline in Older AdultsJournal of the American Geriatrics Society, 2011
- Examining the Evidence: A Systematic Review of the Inclusion and Analysis of Older Adults in Randomized Controlled TrialsJournal of General Internal Medicine, 2011
- Ageing populations: the challenges aheadThe Lancet, 2009
- How We Design Feasibility StudiesAmerican Journal of Preventive Medicine, 2009
- A perspective on intelligent devices and environments in medical rehabilitationMedical Engineering & Physics, 2008
- The effect of very early mobilisation after stroke on psychological well-beingJournal of Rehabilitation Medicine, 2008
- Member Checking With Older Women: A Framework for Negotiating MeaningHealth Care for Women International, 2007
- Effects of Passive Leg Movement on the Oxygenation Level of Lower Limb Muscle in Chronic Stroke PatientsNeurorehabilitation and Neural Repair, 2007
- Prevalence and Outcomes of Low Mobility in Hospitalized Older PatientsJournal of the American Geriatrics Society, 2004