Planning for mARC treatments with the Eclipse treatment planning system
Open Access
- 8 March 2015
- journal article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 16 (2) , 458-464
Abstract
While modulated arc (mARC) capabilities have been available on Siemens linear accelerators for almost two years now, there was, until recently, only one treatment planning system capable of planning these treatments. The Eclipse treatment planning system now offers a module that can plan for mARC treatments. The purpose of this work was to test the module to determine whether it is capable of creating clinically acceptable plans. A total of 23 plans were created for various clinical sites and all plans delivered without anomaly. The average 3%/3 mm gamma pass rate for the plans was 98.0%, with a standard deviation of 1.7%. For a total of 14 plans, an equivalent static gantry IMRT plan was also created to compare delivery time. In all but two cases, the mARC plans delivered significantly faster than the static gantry plan. We have confirmed the successful creation of mARC plans that are deliverable with high fidelity on an ARTISTE linear accelerator, thus demonstrating the successful implementation of the Eclipse mARC module.PACS numbers: 87.55.D‐, 87.55.ne, 87.57.uq,Keywords
This publication has 23 references indexed in Scilit:
- Commissioning and first clinical application of mARC treatmentStrahlentherapie und Onkologie, 2014
- CRT combined with a sequential VMAT boost in the treatment of upper thoracic esophageal cancerJournal of Applied Clinical Medical Physics, 2013
- A novel implementation of mARC treatment for non-dedicated planning systems using converted IMRT plansRadiation Oncology, 2013
- Node-positive left-sided breast cancer: does VMAT improve treatment plan quality with respect to IMRT?Strahlentherapie und Onkologie, 2013
- Comparative analysis of SmartArc‐based dual arc volumetric‐modulated arc radiotherapy (VMAT) versus intensity‐modulated radiotherapy (IMRT) for nasopharyngeal carcinomaJournal of Applied Clinical Medical Physics, 2011
- A planning and delivery study of a rotational IMRT technique with burst deliveryMedical Physics, 2011
- Single fraction radiosurgery using Rapid Arc for treatment of intracranial targetsRadiation Oncology, 2010
- IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119Medical Physics, 2009
- Evaluation of the Delta4phantom for IMRT and VMAT verificationPhysics in Medicine & Biology, 2009
- 6 MV dosimetric characterization of the 160 MLC™, the new Siemens multileaf collimatorMedical Physics, 2008