Usefulness of 3D transoesophageal echocardiography for guiding wires and closure devices in mitral perivalvular leaks
Authors:
Open Access
- 13 September 2009
- journal article
- case report
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 10 (8) , 979-981
Abstract
Sixty-three-year-old male patient. Previous history of rheumatic valvular disease. He underwent multiple mitral and aortic valve replacements. Nowadays, he presents a periprosthetic mitral leak. He underwent a leak closure by using a percutaneous approach. During the procedure, the superiority of 3D TEE over 2D TEE was confirmed for wires and device positioning, excluding interference with the prosthesis discs and evaluating the residual periprosthetic regurgitation.Keywords
This publication has 3 references indexed in Scilit:
- Usefulness of Transesophageal Echocardiography in Percutaneous Transcatheter Repairs of Paravalvular Mitral RegurgitationThe American Journal of Cardiology, 2008
- Accurate Localization of Mitral Regurgitant Defects Using Multiplane Transesophageal EchocardiographyThe Annals of Thoracic Surgery, 1998
- Localization of mitral periprosthetic leaks by transesophageal echocardiographyThe American Journal of Cardiology, 1992