Stress Analysis in Maxillary All-On-Four Model
Authors:
Open Access
- 1 August 2015
- journal article
- Published by SciELO Agencia Nacional de Investigacion y Desarrollo (ANID) in International journal of odontostomatology
- Vol. 9 (2) , 205-211
Abstract
The aim of this research was to evaluate the load distribution in tilted distal implants used in the all-onfour system. Two implant schemes were used. In both, two vertical anterior implants and tilted posterior implants were installed, one group with an angulation of 15º and another with an angulation of 35º. The implants were installed together with a bar binding them all in a photoelastic model obtained from a replica of an edentulous maxilla. In this model, loads were produced in the sector of the bar cantilever, the abutment of the tilted implants and over the four implants using devices specially designed for this purpose. The bands were recorded with a digital camera, and the qualitative and quantitative analyses were carried out by means of student's t-test and the Mann-Whitney test in Biostat v. 5.0, considering a level of p<0.05 to establish a statistically significant relation. In the qualitative analysis, the implant with 35º presented the greatest amount of stress on the cantilever forces at cervical level. The quantitative studies showed fewer differences in all aspects assessed, although significant differences were observed between the two systems when loads were applied at cantilever level. It can be concluded that there are minimal differences in the stress distribution when comparing implants with angulations of 15º or 35º. However, there is a greater concentration of stress at the cervical level in implants tilted to 35º.Keywords
This publication has 13 references indexed in Scilit:
- Evaluation of “All‐on‐Four” Concept and Alternative Designs with 3D Finite Element Analysis MethodClinical Implant Dentistry and Related Research, 2012
- Load transfer in tilted implants with varying cantilever lengths in an all‐on‐four situationAustralian Dental Journal, 2012
- “All‐on‐4” Immediate‐Function Concept for Completely Edentulous Maxillae: A Clinical Report on the Medium (3 Years) and Long‐Term (5 Years) OutcomesClinical Implant Dentistry and Related Research, 2011
- The influence of cantilever length and implant inclination on stress distribution in maxillary implant-supported fixed denturesThe Journal of Prosthetic Dentistry, 2011
- Finite‐Element Analysis of Stress on Dental Implant ProsthesisClinical Implant Dentistry and Related Research, 2010
- Tilting of splinted implants for improved prosthodontic support: A two-dimensional finite element analysisThe Journal of Prosthetic Dentistry, 2007
- Stress Distribution after Installation of Fixed Frameworks with Marginal Gaps over Angled and Parallel Implants: A Photoelastic AnalysisJournal of Prosthodontics, 2007
- All‐on‐4 Immediate‐Function Concept with Brånemark System® Implants for Completely Edentulous Maxillae: A 1‐Year Retrospective Clinical StudyClinical Implant Dentistry and Related Research, 2005
- Implant treatment without bone grafting in severely resorbed edentulous maxillaeJournal of Oral and Maxillofacial Surgery, 1999
- Ten‐year survival rates of fixed prostheses on four or six implants ad modum Brånemark in full edentulismClinical Oral Implants Research, 1995