Abstract
In recent years, interest in finding alternatives for the evaluation of mobility has increased. Inertial measurement units (IMUs) stand out for their portability, size, and low price. The objective of this study was to examine the accuracy and repeatability of a commercially available IMU under controlled conditions in healthy subjects. A total of 36 subjects, including 17 males and 19 females were analyzed with a Wiva Science IMU in a corridor test while walking for 10 m and in a threadmill at 1.6 km/h, 2.4 km/h, 3.2 km/h, 4 km/h, and 4.8 km/h for one minute. We found no difference when we compared the variables at 4 km/h and 4.8 km/h. However, we found greater differences and errors at 1.6 km/h, 2.4 km/h and 3.2 km/h, and the latter one (1.6 km/h) generated more error. The main conclusion is that the Wiva Science IMU is reliable at high speeds but loses reliability at low speeds.Keywords
This publication has 48 references indexed in Scilit:
- Evaluation of new suspension system for limb prostheticsBioMedical Engineering OnLine, 2014
- Patient specific ankle-foot orthoses using rapid prototypingJournal of NeuroEngineering and Rehabilitation, 2011
- Detection of anticipatory postural adjustments prior to gait initiation using inertial wearable sensorsJournal of NeuroEngineering and Rehabilitation, 2011
- The Use of Wearable Inertial Motion Sensors in Human Lower Limb Biomechanics Studies: A Systematic ReviewSensors, 2010
- Reliabilitätsstudie zum Ganganalysesystem RehaWatch / Reliability of the novel gait analysis system RehaWatchBiomedical Engineering / Biomedizinische Technik, 2010
- Gait Characteristics of Elderly People With a History of Falls: A Dynamic ApproachPhysical Therapy, 2006
- A reliable gait phase detection systemIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2001
- The Effect of Exercise on Gait Patterns in Older Women: A Randomized Controlled TrialThe Journals of Gerontology, Series A: Biological Sciences and Medical Sciences, 1996
- Is This Walk Normal?Age and Ageing, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986