Selective reagent ion – time-of-flight – mass spectrometric studies of cocaine: investigations of charge and proton transfer reaction processes*
Open Access
- 18 March 2025
- journal article
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (4) , 045007
Abstract
Investigations are reported for the reactions of H3O+.(H2O)n (n = 0 and 1), NO+ and O2 +• with cocaine (C17H21NO4) using a Selective Reagent Ion-Time-of-Flight-Mass Spectrometer (SRI-ToF-MS) covering a range of DC reduced electric field values (from approximately 60 Td up to about 230 Td), with the electric field strength being determined from the total DC voltage drop across the drift tube. In addition to examining the influence of the reduced electric field value on the reagent ion-cocaine product ion types and distributions, the effects of applying a radio frequency (RF) electric field in the ion funnel region of the drift tube are also reported. Observed reaction pathways without (DC mode) and with (DC + RF mode) the ion funnel operating include non-dissociative and dissociative proton transfer for the reactions involving H3O+.(H2O)n (n = 0 and 1), and non-dissociative and dissociative charge transfer for the reactions involving NO+ and O2 +•. Although the dissociative proton transfer pathways leading to product ions with m/z values of 272.129 (C16H18NO3 +), 182.118 (C10H16NO2 +) and 123.045 (C7H7O2 +) are highly exoergic, as determined from density functional theory calculations, non-dissociative proton transfer dominates resulting in C17H21NO4.H+ at m/z 304.155. The significance of the lack of dissociative proton transfer is discussed. Non dissociative charge transfer, leading to C17H22NO4 + at m/z 303.155, dominates up to DC drift tube electric field strengths of about 80 V cm−1, after which the product ion C5H8N+ becomes the dominant product ion. Other product ions resulting from dissociative charge transfer processes that are common to both NO+ and O2 +• reactions with cocaine are C10H16NO2 + and C7H5O+ at m/z 182.118 and 105.034, respectively. The reactions with O2 +• lead to a fourth observed fragment ion at m/z 272.129 corresponding to C16H18NO3 +.Keywords
Funding Information
- eu (101073924)
This publication has 11 references indexed in Scilit:
- Portable testing techniques for the analysis of drug materialsWIREs Forensic Science, 2022
- Studies pertaining to the monitoring of volatile halogenated anaesthetics in breath by proton transfer reaction mass spectrometryJournal of Breath Research, 2020
- Evaluation of false positive responses by mass spectrometry and ion mobility spectrometry for the detection of trace explosives in complex samplesAnalytica Chimica Acta, 2013
- Use of proton transfer reaction time-of-flight mass spectrometry for the analytical detection of illicit and controlled prescription drugs at room temperature via direct headspace samplingAnalytical and Bioanalytical Chemistry, 2011
- Peer Reviewed: Ion Mobility Spectrometers in National Defense2004
- Charge transfer from neutral perfluorocarbons to various cations: long-range versus short-range reaction mechanismsInternational Journal of Mass Spectrometry, 2000
- Collision-induced dissociation mass spectra of cocaine, and its metabolites and pyrolysis productsJournal of Mass Spectrometry, 1998
- Narrow-Bore HPLC in Combination with Fluorescence and Electrospray Mass Spectrometric Detection for the Analysis of Cocaine and Metabolites in Human HairAnalytical Chemistry, 1998
- Evaluated Gas Phase Basicities and Proton Affinities of Molecules: An UpdateJournal of Physical and Chemical Reference Data, 1998
- Determination of proton affinities from the kinetics of proton transfer reactions. VII. The proton affinities of O2, H2, Kr, O, N2, Xe, CO2, CH4, N2O, and COThe Journal of Chemical Physics, 1980