A platform based on a highly selective and sensitive detection device functionalized with a well-designed artificial biointerface is required for versatile biosensors. We develop a molecularly imprinted polymer (MIP)-coated gate field-effect transistor (FET) biosensor for low-concentration-glucose detection in biological fluid samples such as tears in an enzyme-free manner. The MIP includes glucose templates (GluMIP), in which glucose binds to vinylphenylboronic acid (VPBA) in the copolymerized membrane resulting in the change in the density of molecular charges of the PBA/glucose complex. The FET biosensor can detect small biomolecules as long as biomolecular recognition events cause intrinsic changes in the density of molecular charges. As a result, the changes in the output voltage detected using the GluMIP-based FET sensor are fitted to the Langmuir adsorption isotherm equation at various concentrations of sugars, showing the low detection limit of 3 μM and the high sensitivity of 115 mV/decade from 100 μM to 4 mM glucose. On the basis of the equation, the stability constant (Ka) of PBA with glucose is calculated and found to markedly increase to Ka=1192 M-1, which is higher by a factor of a few hundreds than Ka=4.6 M-1 obtained by nonelectrical detection methods. Moreover, the GluMIP-coated gate FET sensor shows an approximately 200-fold higher selectivity for glucose than for fructose. This is because glucose binds to PBA more selectively than fructose in the templates resulting in the generation of negative charges. The electrical properties of the MIP-coated electrode are also evaluated by measuring capacitance and impedance. Our work suggests a new strategy of designing a platform based on the MIP-coated gate FET biosensor, which is suitable for a highly selective, sensitive, enzyme-free biosensing system.Keywords
Funding Information
- Ministry of Education, Culture, Sports, Science and Technology
This publication has 46 references indexed in Scilit:
- Behavior of Phenols and Phenoxyacids on a Bisphenol-A Imprinted Polymer. Application for Selective Solid-Phase Extraction from Water and Urine SamplesInternational Journal of Molecular Sciences, 2011
- Glucose sensors based on electrodeposition of molecularly imprinted polymeric micelles: A novel strategy for MIP sensorsBiosensors and Bioelectronics, 2011
- Fluorescent molecularly imprinted polymer film binds glucose with a concomitant changes in fluorescenceBiosensors and Bioelectronics, 2010
- MIP-based sensor platforms for the detection of histamine in the nano- and micromolar range in aqueous mediaSensors and Actuators B: Chemical, 2010
- Open Sandwich-Based Immuno-Transistor for Label-Free and Noncompetitive Detection of Low Molecular Weight AntigenAnalytical Chemistry, 2009
- Glucose-sensitive field effect transistor using totally synthetic compoundsJournal of Solid State Electrochemistry, 2008
- Home blood glucose biosensors: a commercial perspectiveBiosensors and Bioelectronics, 2005
- Boronic acid compounds as potential pharmaceutical agentsMedicinal Research Reviews, 2003
- Enzyme-linked immunosorbent assay (ELISA) quantitative assay of immunoglobulin GImmunochemistry, 1971