Operator Performance in Surgical Telemanipulation
Author:
- 1 October 2001
- journal article
- Published by MIT Press in PRESENCE: Virtual and Augmented Reality
- Vol. 10 (5) , 495-510
Abstract
The application of telemanipulator systems in minimally invasive surgery (MIS) poses high demands on the quality of force feedback. Forces exerted on the tissue are often small and should be reflected back amplified to the surgeon. The dynamic behavior of a telemanipulator system can be adjusted in three basic ways to guarantee sufficient stability robustness in spite of high force scaling factors: by scaling down the surgeon's input motion, by increasing the compliance at the slave arm, and/or by increasing the motion resistance at the master arm. More “transparent” telemanipulator dynamics can be achieved when the damping provided by the surgeon's hand-arm-system is taken into account (for example, the motion resistance necessary to guarantee stability robustness can be reduced). This paper investigates the effect of the three basic types of telemanipulator dynamics on operator performance in surgical tasks. The impact of improving transparency by making use of operator damping is also studied. Three experiments imitating elementary surgical procedures were conducted: inserting a catheter tip into a vessel, puncturing a membrane, and detecting differences in tissue hardness through palpation. Subjects exerted significantly higher forces when inserting a catheter without force feedback, which shows the benefit of force feedback in surgical telemanipulation. Performance of the subjects was also greatly influenced by the basic type of telemanipulator dynamics. However, differences in outcome between the experiments indicate that the best basic type will generally depend on the surgical task at hand. Improving the transparency of the telemanipulator system by making use of operator damping did not improve performance of the subjects any further. Thus, it appears that providing the appropriate basic type of telemanipulator dynamics for a given task may be even more critical to the performance of the surgeon than an optimized transparency of the telemanipulator dynamics.Keywords
This publication has 7 references indexed in Scilit:
- Control Design and Task Performance in Endoscopic TeleoperationPRESENCE: Virtual and Augmented Reality, 2000
- Fundamental Limits of Performance for Force Reflecting TeleoperationThe International Journal of Robotics Research, 1998
- Telepresence technology in medicine: principles and applicationsProceedings of the IEEE, 1998
- Human factors in telemanipulation: perspectives from the Oak Ridge National Laboratory experience1993
- Operator Performance with Alternative Manual Control Modes in TeleoperationPRESENCE: Virtual and Augmented Reality, 1992
- A design framework for teleoperators with kinesthetic feedbackIEEE Transactions on Robotics and Automation, 1989
- Neural, mechanical, and geometric factors subserving arm posture in humansThe Journal of Neuroscience, 1985