Stent underexpansion is associated with high wall shear stress: a biomechanical analysis of the shear stent study
Authors:
- 29 April 2023
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 39 (7) , 1375-1382
Abstract
Coronary stent underexpansion is associated with restenosis and stent thrombosis. In clinical studies of atherosclerosis, high wall shear stress (WSS) has been associated with activation of prothrombotic pathways, upregulation of matrix metalloproteinases, and future myocardial infarction. We hypothesized that stent underexpansion is predictive of high WSS. WSS distribution was investigated in patients enrolled in the prospective randomized controlled study of angulated coronary arteries randomized to undergo percutaneous coronary intervention with R-ZES or X-EES. WSS was calculated from 3D reconstructions of arteries from intravascular ultrasound (IVUS) and angiography using computational fluid dynamics. A logistic regression model investigated the relationship between WSS and underexpansion and the relationship between underexpansion and stent platform. Mean age was 63±11, 78% were male, 35% had diabetes, mean pre-stent angulation was 36.7°±14.7°. Underexpansion was assessed in 83 patients (6,181 IVUS frames). Frames with stent underexpansion were significantly more likely to exhibit high WSS (> 2.5 Pa) compared to those without underexpansion with an OR of 2.197 (95% CI = [1.233–3.913], p = 0.008). There was no significant association between underexpansion and low WSS (< 1.0 Pa) and no significant differences in underexpansion between R-ZES and X-EES. In the Shear Stent randomized controlled study, underexpanded IVUS frames were more than twice as likely to be associated with high WSS than frames without underexpansion.Keywords
Funding Information
- Medtronic
This publication has 19 references indexed in Scilit:
- Effects of Low Endothelial Shear Stress After Stent Implantation on Subsequent Neointimal Hyperplasia and Clinical Outcomes in HumansJournal of the American Heart Association, 2016
- Effect of Intravascular Ultrasound–Guided vs Angiography-Guided Everolimus-Eluting Stent ImplantationJAMA, 2015
- Impact of local endothelial shear stress on neointima and plaque following stent implantation in patients with ST-elevation myocardial infarction: A subgroup-analysis of the COMFORTABLE AMI–IBIS 4 trialInternational Journal of Cardiology, 2015
- Contemporary Clinical Applications of Coronary Intravascular UltrasoundJACC: Cardiovascular Interventions, 2011
- Coronary Artery Wall Shear Stress Is Associated With Progression and Transformation of Atherosclerotic Plaque and Arterial Remodeling in Patients With Coronary Artery DiseaseCirculation, 2011
- The Effect of Shear Stress on Neointimal Response Following Sirolimus- and Paclitaxel-Eluting Stent Implantation Compared With Bare-Metal Stents in HumansJACC: Cardiovascular Interventions, 2010
- Wall shear over high degree stenoses pertinent to atherothrombosisJournal of Biomechanics, 2010
- Role of Endothelial Shear Stress in the Natural History of Coronary Atherosclerosis and Vascular RemodelingJACC, 2007
- The role of shear stress in the destabilization of vulnerable plaques and related therapeutic implicationsNature Clinical Practice Cardiovascular Medicine, 2005
- Relationship Between Neointimal Thickness and Shear Stress After Wallstent Implantation in Human Coronary ArteriesCirculation, 2001