Simultaneous determination of cobalt and vanadium in undiluted crude oil using high-resolution continuum source graphite furnace atomic absorption spectrometry
Authors:
- 14 January 2010
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 25 (4) , 590-595
Abstract
A fast, simple and sensitive screening method for the simultaneous determination of Co and V in crude oil samples by high-resolution continuum source graphite furnace atomic absorption spectrometry is proposed. The simultaneous determination is possible as two secondary lines for V, at 240.674 nm and 240.789 nm, are in the vicinity of the most sensitive Co line at 240.725 nm and within the wavelength interval covered by the linear charge-coupled device array detector. The samples have been analyzed directly without dilution after a 10-minute homogenization in an ultrasonic bath. Aliquots of 0.6–8.0 mg have been weighed onto solid-sampling platforms and a chemical modifier solution of Pd and Triton X-100 has been added over the samples. Although the volatility of the two analytes is different, it has been no problem to find compromise conditions, i.e., a pyrolysis temperature of 1300 °C, and an atomization temperature of 2650 °C; aqueous standard solutions have been used for calibration. Two certified oil reference materials have been analyzed to validate the accuracy of the method, and the results were in agreement with the certified or reported values, according to the t-test for a 95% confidence level. The limits of detection (3 σ, n = 10) were 8 μg kg−1 for Co and 1.2 mg kg−1 for V, as a secondary, less sensitive line has been used for the determination of this element. Five crude oils samples were analyzed using the proposed procedure. The precision, expressed as RSD, ranged from 3 to 13% for Co, and from 7 to 24% for V, except for one sample, the V content of which was very close to the limit of quantification.Keywords
This publication has 25 references indexed in Scilit:
- Direct and simultaneous determination of Cr and Fe in crude oil using high-resolution continuum source graphite furnace atomic absorption spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2009
- Frontiers in Green Chemistry: meeting the grand challenges for sustainability in R&D and manufacturingJournal of Cleaner Production, 2008
- Feasibility of peak volume, side pixel and multiple peak registration in high-resolution continuum source atomic absorption spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2007
- Determination of copper, iron and vanadium in petroleum by direct sampling electrothermal atomic absorption spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2007
- Feasibility of using solid sampling graphite furnace atomic absorption spectrometry for speciation analysis of volatile and non-volatile compounds of nickel and vanadium in crude oilTalanta, 2007
- Current Status of Direct Solid Sampling for Electrothermal Atomic Absorption Spectrometry—A Critical Review of the Development between 1995 and 2005Applied Spectroscopy Reviews, 2006
- Speciation analysis of volatile and non-volatile vanadium compounds in Brazilian crude oils using high-resolution continuum source graphite furnace atomic absorption spectrometryAnalytica Chimica Acta, 2006
- Palladium as chemical modifier for the stabilization of volatile nickel and vanadium compounds in crude oil using graphite furnace atomic absorption spectrometryJournal of Analytical Atomic Spectrometry, 2005
- Trace element determination in crude oil and its fractions by inductively coupled plasma mass spectrometry using ultrasonic nebulization of toluene solutionsSpectrochimica Acta Part B: Atomic Spectroscopy, 2002
- Extended calibration ranges for continuum source atomic absorption spectrometry with array detectionSpectrochimica Acta Part B: Atomic Spectroscopy, 1996