An NFC on Two-Coil WPT Link for Implantable Biomedical Sensors under Ultra-Weak Coupling
Open Access
Abstract
The inductive link is widely used in implantable biomedical sensor systems to achieve near-field communication (NFC) and wireless power transfer (WPT). However, it is tough to achieve reliable NFC on an inductive WPT link when the coupling coefficient is ultra-low (0.01 typically), since the NFC signal (especially for the uplink from the in-body part to the out-body part) could be too weak to be detected. Traditional load shift keying (LSK) requires strong coupling to pass the load modulation information to the power source. Instead of using LSK, we propose a dual-carrier NFC scheme for the weak-coupled inductive link; using binary phase shift keying (BPSK) modulation, its downlink data are modulated on the power carrier (2 MHz), while its uplink data are modulated on another carrier (125 kHz). The two carriers are transferred through the same coil pair. To overcome the strong interference of the power carrier, dedicated circuits are introduced. In addition, to minimize the power transfer efficiency decrease caused by adding NFC, we optimize the inductive link circuit parameters and approach the receiver sensitivity limit. In the prototype experiments, even though the coupling coefficient is as low as 0.008, the in-body transmitter costs only 0.61 mW power carrying 10 kbps of data, and achieves a 1 × 10 bit error rate under the strong interference of WPT. This dual-carrier NFC scheme could be useful for small-sized implantable biomedical sensor applications.
Keywords
Funding Information
- National Natural Science Foundation of China (31427801)
This publication has 30 references indexed in Scilit:
- A Circadian and Cardiac Intraocular Pressure Sensor for Smart Implantable LensIEEE Transactions on Biomedical Circuits and Systems, 2016
- Optimal Coupling to Achieve Maximum Output Power in a WPT SystemIEEE Transactions on Power Electronics, 2015
- Telemetry for Implantable Medical Devices: Part 2 - Power TelemetryIEEE Solid-State Circuits Magazine, 2014
- The Circuit Theory Behind Coupled-Mode Magnetic Resonance-Based Wireless Power TransmissionIEEE Transactions on Circuits and Systems I: Regular Papers, 2012
- IOP: quantity and quality.2011
- An RFID-Based Closed-Loop Wireless Power Transmission System for Biomedical ApplicationsIEEE Transactions on Circuits and Systems II: Express Briefs, 2010
- Modeling and Optimization of Printed Spiral Coils in Air, Saline, and Muscle Tissue EnvironmentsIEEE Transactions on Biomedical Circuits and Systems, 2009
- An inductive power system with integrated bi-directional data-transmissionSensors and Actuators A: Physical, 2004
- The dielectric properties of biological tissues: I. Literature surveyPhysics in Medicine & Biology, 1996
- The probability of having glaucoma at different IOP levelsActa Ophthalmologica, 1991