X‐ray micro‐computed tomography in the assessment of penile cavernous fibrosis in a rabbit castration model
Abstract
Background: Current assessment methods of penile cavernous fibrosis in animal models have limitations due to the inability to provide complex and volume analysis of fibrotic alterations.Objective: The aim was to evaluate micro‐computed tomography for assessment of cavernous fibrosis and compare it with histological, histochemical, immunohistochemical, and RT‐PCR analysis.Materials and methods: A controlled trial was performed involving 25 New Zealand male rabbits with induced testosterone deficiency by orchidectomy. Penile samples were obtained before and after 7, 14, 21, and 84 days from orchidectomy. We consistently performed (a) gray value analysis of corpora cavernosa 3D models reconstructed after micro‐computed tomography, (b) morphometry of smooth muscles/connective tissue ratio, collagen type I/III ratio, and area of TGF‐beta‐1 expression in corpora cavernosa, and (c) RT‐PCR of TGF‐beta‐1 expression.Results: Micro‐computed tomography allowed visualization of penile structures at a resolution comparable to light microscopy. Gray values of corpora cavernosa decreased from 1673 (1512–1773) on the initial day to 1184 (1089–1232) on the 21st day (p < 0.005). However, on the 84th day, it increased to 1610 (1551–1768). On 21st and 84th days, there was observed a significant decrease in smooth muscle/connective tissue ratio and a significant increase in collagen type I/III ratio (p < 0.05). TGF‐beta1 expression increased on the 84th day according to immunohistochemistry (p < 0.005). RT‐PCR was impossible to conduct due to the absence of RNA in obtained samples after micro‐CT.Discussion and conclusions: Micro‐computed tomography provided 3D visualization of entire corpora cavernosa and assessment of radiodensity alterations by gray value analysis in fibrosis progression. We speculate that gray value changes at early and late fibrosis stages could be related to tissue reorganization. RT‐PCR is impossible to conduct on tissue samples studied by micro‐CT due to RNA destruction. We also suggest that micro‐computed tomography could negatively affect the immunohistochemical outcome, as a significant increase of TGF‐beta‐1 expression occurs later than histological fibrotic signs.Keywords
Funding Information
- Foundation for Assistance to Small Innovative Enterprises in Science and Technology (15849ГУ/2020)
- Ministry of Science and Higher Education of the Russian Federation (BAZ 0110/20‐5‐14AB)
- Megagrants (14.Z50.31.0046)
This publication has 44 references indexed in Scilit:
- Three-dimensional non-destructive soft-tissue visualization with X-ray staining micro-tomographyScientific Reports, 2015
- Castration impairs erectile organ structure and function by inhibiting autophagy and promoting apoptosis of corpus cavernosum smooth muscle cells in ratsInternational Urology and Nephrology, 2015
- Morphological Characterisation of Unstained and Intact Tissue Micro-architecture by X-ray Computed Micro- and Nano-TomographyScientific Reports, 2015
- Fibrotic Protein Expression Profiles in Penile Tissue of Patients With Erectile DysfunctionUrology, 2013
- Effects of Chronic Stress on Penile Corpus Cavernosum of RatsJournal of Andrology, 2012
- Deriving Hounsfield units using grey levels in cone beam computed tomographyDentomaxillofacial Radiology, 2010
- Amelioration of Penile Fibrosis: Myth or RealityJournal of Andrology, 2010
- Application of micro-CT in small animal imagingMethods, 2010
- Effects of Prolonged Formalin Fixation on Diagnostic Immunohistochemistry in Domestic AnimalsJournal of Histochemistry & Cytochemistry, 2009
- CORPOREAL STRUCTURAL AND VASCULAR MICRO ARCHITECTURE WITH X-RAY MICRO COMPUTERIZED TOMOGRAPHY IN NORMAL AND DIABETIC RABBITS: HISTOPATHOLOGICAL CORRELATIONJournal of Urology, 2001