A Fast Faulty Phase Selection Method Considering Fault Tolerance for Single Phase to Ground Fault in Distribution Networks
- 25 September 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-12
Abstract
Faulty phase selection (FPS) methods are used to solve the problem of single phase to ground fault (SPGF) in the distribution network. When a false FPS (FFPS) issue occurs, the short-circuit current in the faulty line suddenly increases. It is crucial to diminish damages caused by the FFPS issue and rapidly re-select the faulty phase. Therefore, this paper proposes a fault-tolerant method based on an active-intervention-type arc suppression device with a soft switch mode (AASD-SSM) and a fast FPS method based on wavelet packet transform (WPT). To strengthen the fault-tolerant performance of FPS, the AASD-SSM is first developed with an intermediate resistance and a soft switch. Then the value of intermediate resistance is determined by the short-circuit current in AASD-SSM. To realize the accuracy and rapidity of FPS, a modified WPT (MWPT) method based on frequency band energy is presented. In different fault scenarios, the number of wavelet decomposition layer is updated by MWPT and the SPGF issues in the faulty lines can be monitored in real-time. Simulation results demonstrate that AASD-SSM improves the fault-tolerant performance of FPS. The phase selection accuracy of MWPT is better than that of WPT in all fault scenarios and the computational complexity of MWPT is reduced for more than 10%.Keywords
Funding Information
- National Natural Science Foundation of China-State Grid Joint Fund for Smart Grid (U2066210)
This publication has 28 references indexed in Scilit:
- Fault Analysis and Fault-Tolerant Design for Parallel Redundant Inverter Systems in Case of IGBT Short-Circuit FailuresIEEE Journal of Emerging and Selected Topics in Power Electronics, 2018
- Detecting Single-Phase-to-Ground Fault Event and Identifying Faulty Feeder in Neutral Ineffectively Grounded Distribution SystemIEEE Transactions on Power Delivery, 2017
- Fault Location in Resonant Grounded Network by Adaptive Control of Neutral-to-Earth Complex ImpedanceIEEE Transactions on Power Delivery, 2017
- Resilience Enhancement of Microgrids With Inverter-Interfaced DGs by Enabling Faulty Phase SelectionIEEE Transactions on Smart Grid, 2017
- Design, Control, and Analysis of a Fault-Tolerant Soft-Switching DC–DC Converter for High-Power High-Voltage ApplicationsIEEE Transactions on Power Electronics, 2017
- A Fault-Tolerant T-Type Multilevel Inverter Topology With Increased Overload Capability and Soft-Switching CharacteristicsIEEE Transactions on Industry Applications, 2017
- Principle and Control Design of Active Ground-Fault Arc Suppression Device for Full Compensation of Ground CurrentIEEE Transactions on Industrial Electronics, 2017
- A Phase Selection Method for Wind Power Integration System Using Phase Voltage Waveform CorrelationIEEE Transactions on Power Delivery, 2016
- A Novel Method of Ground Fault Phase Selection in Weak-Infeed SideIEEE Transactions on Power Delivery, 2014
- Fault Classification and Faulted-Phase Selection Based on the Initial Current Traveling WaveIEEE Transactions on Power Delivery, 2008