Comparison of Reconstruction Methods in a Small Animal Cardiac Positron Emission Tomography Study Using a 18F-Labeled Myocardial Agent, [18F] FPTP
Authors:
- Hyeon-Sik KimHKHyeon-Sik Kim
- Byeong-Il LeeBLByeong-Il Lee
- Ju Han KimJKJu Han Kim
- Hee-Seung BomHBHee-Seung Bom
- Dong-Yeon KimDKDong-Yeon Kim
- Jung-Joon MinJMJung-Joon Min
Open Access
- 10 August 2016
- journal article
- Published by Brieflands in Iranian Journal of Radiology
- Vol. 14 (1)
Abstract
Background: Reconstruction of positron emission tomography (PET) imagery is essential for accurate diagnosis in nuclear medicine. Thus, several image reconstruction methods were developed to enhance image quality and accuracy. Objectives: We performed PET studies using a new myocardial imaging agent, (5-[18F] fluoropentyl) triphenylphosphonium cation ([18F]FPTP), in left coronary artery (LCA)-occluded rats, and compared the quality of cardiac PET images generated via four reconstruction methods (FBP, OSEM2D, OSEM3D, and 3DRP). Additionally, the infarction size was measured on the polar map of each reconstructed image and compared with defect size measured via 2, 3, 5-triphenyltetrazolium chloride (TTC) staining. Materials and Methods: MicroPET was performed in Sprague-Dawley rats (n = 8) with LCA ligation. Static images were acquired for 30 min after the injection of [18F] FPTP (37 MBq/200 µL) via tail vain. MicroPET images were generated using four different reconstruction methods: filtered backprojection (FBP), two-dimensional or three-dimensional ordered subsets expectation maximization (OSEM2D or OSEM3D), and three-dimensional reprojection (3DRP) algorithm. Image contrast was calculated using the maximum and minimum perfusion values in the polar map. The infarction size was measured on the polar map of each reconstructed image and compared with defect size measured from TTC staining. Results: The location and size of myocardial infarction on PET images correlated closely with that observed with TTC staining. Among the four reconstruction methods, OSEM3D provided the best assessment of infarct size (r2 = 0.994, P < 0.001) and the highest image contrast, performing significantly better than FBP (P = 0.005) and 3DRP (P = 0.005). Conclusion: OSEM3D may provide better image quality and higher contrast than other methods for small animal imaging with the new myocardial imaging agent, [18F] FPTP. Keywords: Myocardial Perfusion Imaging; [18F] FPTP; Image Reconstruction; Myocardial Infarction; OSEM3DKeywords
This publication has 23 references indexed in Scilit:
- Synthesis of [18F]-labeled (2-(2-fluoroethoxy)ethyl)tris(4-methoxyphenyl)phosphonium cation as a potential agent for positron emission tomography myocardial imagingNuclear Medicine and Biology, 2012
- Synthesis of [18F]-Labeled (6-Fluorohexyl)triphenylphosphonium Cation as a Potential Agent for Myocardial Imaging using Positron Emission TomographyBioconjugate Chemistry, 2012
- Evaluation of iterative reconstruction (OSEM) versus filtered back-projection for the assessment of myocardial glucose uptake and myocardial perfusion using dynamic PETEuropean Journal of Nuclear Medicine and Molecular Imaging, 2006
- Comparison of ANalytic and Iterative Reconstruction Methods for Quantitative Cardiac PET Studies Using 3D Oxygen-15 Water Scans2006
- Evaluation of 3D reconstruction algorithms for a small animal PET cameraIEEE Transactions on Nuclear Science, 1997
- Exact and approximate rebinning algorithms for 3-D PET dataIEEE Transactions on Medical Imaging, 1997
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994
- Iterative image reconstruction for positron emission tomography: a study of convergence and quantitation problemsIEEE Transactions on Nuclear Science, 1990
- The Theory of Three-Dimensional Image Reconstruction for PETIEEE Transactions on Medical Imaging, 1987
- Maximum Likelihood Reconstruction for Emission TomographyIEEE Transactions on Medical Imaging, 1982