Hyperpolarized 129Xe gas transfer MRI: the transition from 1.5T to 3T
- 19 July 2018
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 80 (6) , 2374-2383
Abstract
Purpose: Hyperpolarized 129Xe MRI depicting 3D ventilation, interstitial barrier uptake, and transfer to red blood cells (RBCs) has emerged as a powerful new means of detecting pulmonary disease. However, given the challenging susceptibility environment of the lung, such gas transfer imaging has, thus far, only been implemented at 1.5T. Here, we seek to demonstrate the feasibility of Dixon‐based 129Xe gas transfer MRI at 3T.Methods: Seven healthy subjects and six patients with pulmonary disorders were recruited to characterize 129Xe spectral structure, optimize acquisition parameters, and acquire representative images. Imaging used randomized, gradient‐spoiled 3D‐radial encoding of 1000 gas (0.5° flip) and dissolved (20° flip) views, reconstructed into 3‐mm isotropic voxels. The center of k‐space was sampled when barrier and RBC compartments were 90° out of phase (TE90). A single dissolved phase spectrum was appended to the sequence to measure the global RBC–barrier ratio for Dixon‐based decomposition.Results: A 0.69 ms sinc was found to generate minimal off‐resonance gas‐phase excitation (3.0 ± 0.3% of the dissolved‐phase), yielding a TE90 = 0.47 ± 0.02 ms. The RBC and barrier resonance frequencies were shifted by 217.6 ± 0.6 ppm and 197.8 ± 0.2 ppm. The RBC was estimated to be ∼1.1 ms, and therefore each read‐out was limited to 1.3 ms. 129Xe gas and dissolved‐phase images have sufficient SNR to produce gas transfer maps of similar quality and sensitivity to pathology, as previously obtained at 1.5T.Conclusions: Despite short dissolved‐phase , 129Xe gas transfer MRI is feasible at 3T.Keywords
Funding Information
- National Institutes of Health (R01HL126771, R01HL105643, HHSN268201700001C)
- National Heart, Lung, and Blood Institute
This publication has 22 references indexed in Scilit:
- 3D MRI of impaired hyperpolarized 129Xe uptake in a rat model of pulmonary fibrosisNMR in Biomedicine, 2014
- Radiofrequency pulse design for the selective excitation of dissolved129XeMagnetic Resonance in Medicine, 2014
- Regional mapping of gas uptake by blood and tissue in the human lung using hyperpolarized xenon‐129 MRIJournal of Magnetic Resonance Imaging, 2013
- Hyperpolarized 129Xe gas lung MRI–SNR and T2* comparisons at 1.5 T and 3 TMagnetic Resonance in Medicine, 2012
- Simultaneous magnetic resonance imaging of ventilation distribution and gas uptake in the human lung using hyperpolarized xenon-129Proceedings of the National Academy of Sciences, 2010
- Quantitative MRI measurement of lung density must account for the change in T with lung inflationJournal of Magnetic Resonance Imaging, 2009
- Chronic thromboembolic pulmonary hypertension — assessment by magnetic resonance imagingEuropean Radiology, 2006
- High-volume production of laser-polarized 129XeApplied Physics Letters, 1996
- Boron‐11 imaging with a three‐dimensional reconstruction methodJournal of Magnetic Resonance Imaging, 1992
- Notes on the uniform distribution of sequences of integersProceedings of the Japan Academy, Series A, Mathematical Sciences, 1968