Design and Assessment of a Miniaturized Amperometric Oxygen Sensor in Rats and Pigs
Authors:
- 27 May 2010
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 10 (7) , 1259-1265
Abstract
The purpose of this project was to assess whether a novel, small diameter two-electrode oxygen sensor is capable of early detection of hemorrhage-induced hypoperfusion in rats and pigs. Hemorrhage is a very common cause of death after trauma and the degree of blood loss is difficult to gauge. In order to monitor blood volume, we developed a sensor designed to rapidly respond to changes in subcutaneous oxygen tension. The oxygen sensor included a platinum indicating electrode and a AgCl-based reference electrode. When tested in rats and pigs during controlled hemorrhage, the signals from these subcutaneously implanted sensors closely tracked the mean blood pressure and venous pO2. The sensor signals declined quickly during blood withdrawal and rose quickly in response to fluid resuscitation. Pulse rate was not a reliable indicator of blood loss. The signals of the oxygen sensors declined (negative slope) during hemorrhage and rose (positive slope) during resuscitation. In all cases, in both rats and pigs, slopes of less than -0.1 Torr/min indicated hemorrhage and slopes of more than 0.1 indicated resuscitation. Given the similarities of skin and subcutaneous tissue in pigs versus humans, devices like this may be useful for early detection of hemorrhage in humans.Keywords
This publication has 27 references indexed in Scilit:
- Causes of Death in U.S. Special Operations Forces in the Global War on TerrorismAnnals of Surgery, 2007
- A PROSPECTIVE RANDOMIZED TRIAL COMPARING OXYGEN DELIVERY VERSUS TRANSCUTANEOUS PRESSURE OF OXYGEN VALUES AS RESUSCITATIVE GOALSShock, 2007
- A flexible transcutaneous oxygen sensor using polymer membranesBiomedical Microdevices, 2006
- TRANSCUTANEOUS PRESSURE OF OXYGENShock, 2006
- Histology of the thick scar on the female, red Duroc pig: Final similarities to human hypertrophic scarBurns, 2006
- Variants of the tissue-sensor array window chamberAmerican Journal of Physiology-Heart and Circulatory Physiology, 2005
- A Comparison of the Failure Times of Pulse Oximeters During Blood Pressure Cuff-Induced Hypoperfusion in VolunteersAnesthesia & Analgesia, 2004
- Continuous amperometric monitoring of subcutaneous oxygen in rabbit by telemetryJournal of Medical Engineering & Technology, 2002
- Subcutaneous Tissue Oxygen PressureThe Journal of Trauma: Injury, Infection, and Critical Care, 1996
- Design and validation of the transparent oxygen sensor arrayIEEE Transactions on Biomedical Engineering, 1991