Abstract
Background: The authors sought to determine the level of inspiratory pressure minimizing the risk of gastric insufflation while providing adequate pulmonary ventilation. The primary endpoint was the increase in incidence of gastric insufflation detected by ultrasonography of the antrum while inspiratory pressure for facemask pressure-controlled ventilation increased from 10 to 25 cm H2O. Methods: In this prospective, randomized, double-blind study, patients were allocated to one of the four groups (P10, P15, P20, and P25) defined by the inspiratory pressure applied during controlled-pressure ventilation: 10, 15, 20, and 25 cm H2O. Anesthesia was induced using propofol and remifentanil; no neuromuscular-blocking agent was administered. Once loss of eyelash reflex occurred, facemask ventilation was started for a 2-min period while gastric insufflation was detected by auscultation and by real-time ultrasonography of the antrum. The cross-sectional antral area was measured using ultrasonography before and after facemask ventilation. Respiratory parameters were recorded. Results: Sixty-seven patients were analyzed. The authors registered statistically significant increases in incidences of gastric insufflation with inspiratory pressure, from 0% (group P10) to 41% (group P25) according to auscultation, and from 19 to 59% according to ultrasonography. In groups P20 and P25, detection of gastric insufflation by ultrasonography was associated with a statistically significant increase in the antral area. Lung ventilation was insufficient for group P10. Conclusion: Inspiratory pressure of 15 cm H2O allowed for reduced occurrence of gastric insufflation with proper lung ventilation during induction of anesthesia with remifentanil and propofol in nonparalyzed and nonobese patients. (Anesthesiology 2014; 120:326-34)Keywords
This publication has 40 references indexed in Scilit:
- Gastric Sonography in the Fasted Surgical PatientAnesthesia & Analgesia, 2011
- Clinical Assessment of the Ultrasonographic Measurement of Antral Area for Estimating Preoperative Gastric Content and VolumeAnesthesiology, 2011
- A Two-handed Jaw-thrust Technique Is Superior to the One-handed “EC-clamp” Technique for Mask Ventilation in the Apneic Unconscious PersonAnesthesiology, 2010
- Rapid Sequence Induction and IntubationAnesthesia & Analgesia, 2010
- Could a single standardized ultrasonographic measurement of antral area be of interest for assessing gastric contents? A preliminary reportEuropean Journal of Anaesthesiology, 2009
- Comparison of three modes of positive pressure mask ventilation during induction of anaesthesia: a prospective, randomized, crossover studyEuropean Journal of Anaesthesiology, 2009
- Laryngeal injuries and intubating conditions with or without muscular relaxation: an equivalence studyCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2008
- Survey of Anesthesia-related Mortality in FranceAnesthesiology, 2006
- A review of patients with pulmonary aspiration of gastric contents during anesthesia reported to the Departmental Quality Assurance CommitteeJournal of Clinical Anesthesia, 2006
- A Coefficient of Agreement for Nominal ScalesEducational and Psychological Measurement, 1960