Direct 4D PET MLEM reconstruction of parametric images using the simplified reference tissue model with the basis function method
Authors:
- 1 October 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Abstract
The purpose of this work is to assess the one-step late maximum likelihood expectation maximization (OSL-MLEM) direct 4D PET reconstruction algorithm when using the simplified reference tissue model with the basis function method (SRTM-BFM). To date, the OSL-MLEM method has been evaluated using kinetic models based on two-tissue compartments with an irreversible component. We therefore extend the evaluation of this method for two-tissue compartments with a reversible component, using SRTM-BFM on simulated 2D and 3D + time data sets (with use of [ 11 C]raclopride time-activity curves (TACs) from real data) and on real data sets acquired with the high resolution research tomograph (HRRT). Furthermore, this work investigates the impact of correcting the TACs by the frame length, as assumed by most conventional kinetic parameter estimation techniques (applied post-reconstruction) used in practice. The performance of the proposed method is evaluated by comparing binding potential (BP) estimates with those obtained from conventional post-reconstruction kinetic parameter estimation. It is shown that, for the 2D + time simulation, SRTM-BFM within the OSL-MLEM framework delivers lower % BIAS and % CV, and thus lower % RMSE, in BP estimates compared to the post reconstruction approach, while for the real 3D data set the method delivers lower spatial % CV, in addition to better BP parametric image quality, when using resolution modeling. Finally, frame length correction can be applied but correct weighting is necessary to obtain the best performance.Keywords
This publication has 14 references indexed in Scilit:
- An Optimization Transfer Algorithm for Nonlinear Parametric Image Reconstruction From Dynamic PET DataIEEE Transactions on Medical Imaging, 2012
- Direct reconstruction of parametric images using any spatiotemporal 4D image based model and maximum likelihood expectation maximisation2010
- Generalized Algorithms for Direct Reconstruction of Parametric Images From Dynamic PET DataIEEE Transactions on Medical Imaging, 2009
- Performance evaluation of the ECAT HRRT: an LSO-LYSO double layer high resolution, high sensitivity scannerPhysics in Medicine & Biology, 2007
- Parametric Imaging of Ligand-Receptor Binding in PET Using a Simplified Reference Region ModelNeuroImage, 1997
- Simplified Reference Tissue Model for PET Receptor StudiesNeuroImage, 1996
- Comparison of Methods for Analysis of Clinical [11C]Raclopride StudiesJournal of Cerebral Blood Flow & Metabolism, 1996
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994
- Maps of receptor binding parameters in the human brain ? a kinetic analysis of PET measurementsEuropean Journal of Nuclear Medicine and Molecular Imaging, 1990
- Maximum Likelihood Reconstruction for Emission TomographyIEEE Transactions on Medical Imaging, 1982