Out-of-Plane Seismic Performance and Detailing of Brick Veneer Walls
- 1 July 2010
- journal article
- research article
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 136 (7) , 781-794
Abstract
The out-of-plane seismic performance of residential brick veneer walls built over wood-frame backup was evaluated as a function of construction detailing. Shake table tests were conducted on a full-scale brick veneer wall panel, with a window opening, representing the gable-end wall of a typical home structure; the structural performance of corrugated sheet metal veneer-to-wood tie connections was also characterized by separate laboratory testing. The wall panel test specimen was prepared following typical construction practice for brick veneer wall systems, in general conformance with current specified prescriptive design and construction requirements. The shake table tests captured the performance of the brick veneer wall system, including interaction and load-sharing between the brick veneer, corrugated sheet metal ties, and wood-frame backup. Detailed three-dimensional finite-element (FE) models were also developed representing the full-scale brick veneer wall panel specimen, including nonlinear inelastic properties for the tie connections. After calibration based on test results, the FE wall panel model effectively captured static and dynamic experimental brick veneer wall behavior at different response levels, up to and including tie damage and even instability/collapse of the wall panel. Parametric studies were then carried out using FE wall panel models to evaluate the effects of certain types and layouts of tie connections, as well as geometric variations in brick veneer wall construction. Overall seismic performance of brick veneer walls was closely related to the individual tie connection deformation limits, especially for damage in tension. The grid spacing of tie connections, as well as tie installation along the edges and in upper regions of the walls, controlled the ultimate behavior of the brick veneer wall panels. Design guides, codes, and current construction practices have been evaluated in light of the overall findings from these experimental and analytical studies.Keywords
This publication has 14 references indexed in Scilit:
- Cyclic testing of unreinforced masonry walls in two‐way bendingEarthquake Engineering & Structural Dynamics, 2006
- Analysis of brick veneer walls on wood frame construction subjected to out-of-plane loadsConstruction and Building Materials, 2005
- Out-of-plane performance of brick veneer walls on wood frame constructionEngineering Structures, 2004
- Gable-End Wall Stability in Florida Hurricane Regions, 10-Year Review: Post-Hurricane Andrew (1992) to Florida Building Code (2002)Journal of Architectural Engineering, 2004
- Performance of Corrugated Metal Ties for Brick Veneer Wall SystemsJournal of Materials in Civil Engineering, 2004
- Analysis of load in ties in masonry veneer wallsCanadian Journal of Civil Engineering, 2003
- Displacement‐based seismic analysis for out‐of‐plane bending of unreinforced masonry wallsEarthquake Engineering & Structural Dynamics, 2002
- Out-of-Plane Seismic Evaluation and Retrofit of Turn-of-the-Century North American Masonry WallsJournal of Structural Engineering, 2001
- Mathematical Modeling of Brick Veneer with Steel‐Stud Backup Wall SystemsJournal of Structural Engineering, 1991
- The response of low-rise non-engineered structures to extreme wind conditionsJournal of Wind Engineering and Industrial Aerodynamics, 1986