Numerical simulation of CuCr alloys vacuum arc under conditions of arc contraction, deflection, and anode vapor
Open Access
- 1 December 2024
- journal article
- research article
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (12)
Abstract
In practical arc ignition processes of high-current vacuum arcs, despite the calibration effect of the axial magnetic field, the strong magnetic constriction force still causes the arc to contract. Additionally, during the actual electrode opening process, due to the random nature of the arcing position, the center of the arc column is often not located at the center of the electrode. At this point, the behavior of the vacuum arc can be understood as an asymmetric three-dimensional (3D) process under the influence of the spatial magnetic field, affecting the generation of anode vapor and the characteristics of arc species. Therefore, it is useful to conduct simulation studies on multi-species vacuum arc behavior considering arc contraction and arc deflection. In this paper, the spatial magnetic field distribution under different electrode effective areas and different arc center deflection distances have been simulated, and the influence of actual magnetic field-induced by arc contraction and deflection on 3D spatial distribution characteristics of arc plasma has been studied based on a 3D multi-species (CuCr alloys) vacuum arc model with anode vapor. The simulation results show that with the contraction of the arc column, the area occupied by neutral atomic vapor decreases correspondingly, but the ionization and recombination process between the arc column regions becomes more intense. The axial current density and electron temperature distribution around the neutral atomic vapor area become more non-uniform. When the arc column deviates from electrode center, the neutral atomic vapor area shows an asymmetrical distribution on both sides of the arc column center axis, and the axial current density and electron temperature gather and enhance in the opposite direction of the arc deflection, thereby significantly affecting the distribution of arc species.Keywords
Funding Information
- National Natural Science Foundation of China (52377157)
- State Key Laboratory of Electrical Insulation and Power Equipment (EIPE22125)
This publication has 22 references indexed in Scilit:
- Three-dimensional modeling of multi-component vacuum arc considering anode vapor in actual magnetic fieldPhysics of Fluids, 2024
- Modeling of vacuum arc plasmas in anode spot or anode plume mode taking into account multiple ion componentsJournal of Applied Physics, 2019
- Study of vacuum arc behavior under anode spot and anode plume modesApplied Physics Letters, 2019
- Overview spectra and axial distribution of spectral line intensities in a high-current vacuum arc with CuCr electrodesJournal of Applied Physics, 2015
- Modeling and Simulation of Deflected Anode Erosion in Vacuum ArcsPlasma Science and Technology, 2014
- Three-dimensional model and simulation of vacuum arcs under axial magnetic fieldsPhysics of Plasmas, 2012
- Anode phenomena in arc discharges: a reviewPlasma Sources Science and Technology, 2011
- High-current vacuum arc under axial magnetic field: Numerical simulation and comparisons with experimentsJournal of Applied Physics, 2006
- 2D expansion of the low-density interelectrode vacuum arc plasma jet in an axial magnetic fieldJournal of Physics D: Applied Physics, 1996
- Magnetic constriction effects in high-current vacuum arcs prior to the release of anode vaporJournal of Applied Physics, 1977