The Effect of Electrode Placement and Interphase Interval on Force Production During Stimulation of the Dorsiflexor Muscles
- 8 July 2014
- journal article
- Published by Wiley in Artificial Organs
- Vol. 38 (11) , E142-6
Abstract
The aims of this study were to investigate whether introducing an interphase interval (IPI) to biphasic pulses during stimulation of the dorsiflexor muscles would affect force production and to determine whether the IPI effect is dependent on electrode position. Twelve healthy volunteers participated in the study. Each subject participated in one session during which electrically induced contraction (EIC) forces of the ankle dorsiflexors were measured with five different IPI settings ranging from 0 to 400 μs. Forces of EICs were assessed with the electrodes placed either with the proximal electrode positioned over the common peroneal nerve and the second electrode over the dorsiflexor muscles or with both electrodes located over the dorsiflexor muscles. The order of electrode placements and of the different IPI settings was randomized across subjects. The results indicated that the introduction of a 100‐μs‐long IPI may enhance force production when one electrode is located over the common peroneal nerve. However, increasing the duration of the IPI beyond 100 μs did not result in further increase in force production. In contrast, the introduction of an IPI did not increase force production when both electrodes were located over the dorsiflexor muscles. These findings may help to optimize stimulation settings during functional electrical stimulation to prevent foot‐drop.Keywords
This publication has 19 references indexed in Scilit:
- A brief interphase interval interposed within biphasic pulses enhances the contraction force of the quadriceps femoris musclePhysiotherapy Theory and Practice, 2012
- Investigation of the Relationship Between Stimulus Parameters and a Human Muscle Contraction Force During Stimulation of the Gastrocnemius MuscleArtificial Organs, 2010
- Electrodes for transcutaneous (surface) electrical stimulationJournal of Automatic Control, 2008
- Effects of neuromuscular electrical stimulation parameters on specific tensionEuropean Journal of Applied Physiology, 2006
- The Therapeutic Effect of Functional and Transcutaneous Electric Stimulation on Improving Gait Speed in Stroke Patients: A Meta-AnalysisArchives of Physical Medicine and Rehabilitation, 2006
- Electrical stimulation of excitable tissue: design of efficacious and safe protocolsJournal of Neuroscience Methods, 2005
- The Orthotic Effect of Functional Electrical Stimulation on the Improvement of Walking in Stroke Patients with a Dropped Foot: A Systematic ReviewArtificial Organs, 2004
- Does the Drop-Foot Stimulator Improve Walking in Hemiplegia?Neuromodulation: Technology at the Neural Interface, 2001
- Effects of waveform parameters on comfort during transcutaneous neuromuscular electrical stimulationAnnals of Biomedical Engineering, 1985
- The response of the myelinated nerve fiber to short duration biphasic stimulating currentsAnnals of Biomedical Engineering, 1979