Abstract
The use of volumetric image data sets in radiotherapy treatment planning has become standard practice and requires an accurate delineation of anatomical structures, a tedious and time consuming task. This has lead to the development of auto‐segmentation approaches for contouring anatomical structures on CT data sets. In this work, we evaluate the accuracy of the ABAS software package (Atlas Based Auto‐Segmentation, version 1.1.0, CMS, Inc, The Elekta Group) for contouring pelvic organs relevant to radiotherapy. The evaluation is based on randomly selected CT data sets of 8 patients treated in our clinic for pelvic malignancies, in which relevant organs have been manually contoured by an oncologist. Each of the 8 CT data sets is used as an atlas to generate contours on all other sets. The resulting ABAS‐generated contours are compared to oncologists ones by means of the Dice coefficient. We find that contours generated by ABAS are best and will require no editing for bony structures such as the femoral heads and the pelvis. For the prostate, bladder and the rectum, ABAS contours are acceptable but will require some editing. However, for the prostate, the presence of fiducial implants could lead to streaking artifacts that degrade the quality of ABAS‐generated contours. For smaller organs with low tissue contrasts such as seminal vesicles and iliac nodes, ABAS results are poor and will lead to no time savings in the radiotherapy process. Finally for organs for which ABAS works well it is quite robust against the variability of the atlas.