Background: Cytological analysis is part of the initial etiological evaluation of serous effusions. The newly proposed International System for Reporting Serous Fluid Cytopathology (ISRSFC) aims to standardize reporting.Methods: All pleural and peritoneal effusion samples admitted for cytological analysis at our institution between 2012 and 2016, and pericardial effusion samples admitted between 2008 and 2018, were reviewed and reclassified according to the ISRSFC. Risk of malignancy (ROM) and performance parameters were calculated.Results: 1496 pleural effusion samples were reclassified: 12(0.8%) non‐diagnostic (ND), 944(63.1%) negative for malignancy (NFM), 9(0.6%) atypia of undetermined significance (AUS), 54(3.6%) suspicious of malignancy (SFM) and 477(31.9%) malignant (M). 64 pericardial effusion samples were reclassified: 23(35.9%) NFM, 1(1.6%) AUS, 4(6.3%) SFM and 36(56.2%) M. 763 peritoneal effusion samples were reclassified: 5(0.7%) ND, 457(59.9%) NFM, 12(1.6%) AUS, 37(4.8%) SFM and 252(33%) M. The ROM was, respectively, for each of the aforementioned categories, 57.1%, 23.9%, 50%, 76.2%, 100% in pleural effusions, 100%, 26.3%, 62.5%, 91.7%, 100% in peritoneal effusions and 0% for NFM, 0% for AUS and 100% for M in pericardial effusions. Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy were, respectively, 61.6%, 100%, 100%, 73.3%, 81.3% for pleural, 100%, 100%, 100%, 100%, 100% for pericardial and 61.2%, 100%, 100%, 70%, 79.7% for peritoneal effusion samples.Conclusion: Serous effusion cytology has a high specificity and positive predictive value and a modest sensitivity and negative predictive value, supporting its role in confirming the diagnosis of malignancy. The ISRSFC will increase standardization and reproducibility in reporting, leading to improved clinical decision‐making.Keywords
This publication has 31 references indexed in Scilit:
- Comparison of diagnostic accuracy between CellprepPlus® and ThinPrep® liquid‐based preparations in effusion cytologyDiagnostic Cytopathology, 2013
- Pericardial fluid cytology: An analysis of 128 specimens over a 6‐year periodCancer Cytopathology, 2013
- Application of Liquid-Based Cytology to Fine-Needle Aspiration Biopsies of the Thyroid GlandFrontiers in Endocrinology, 2012
- Malignant ascites: A review of prognostic factors, pathophysiology and therapeutic measuresWorld Journal of Gastrointestinal Surgery, 2012
- Comparison of the sensitivity of conventional cytology and the ThinPrep Imaging System for 1,083 biopsy confirmed high‐grade squamous lesionsDiagnostic Cytopathology, 2010
- Recent Advances in the Diagnosis and Management of Malignant Pleural EffusionsMayo Clinic Proceedings, 2008
- Accuracy of liquid based versus conventional cytology: overall results of new technologies for cervical cancer screening: randomised controlled trialBMJ, 2007
- The value of ThinPrep and cytospin preparation in pleural effusion cytological diagnosis of mesothelioma and adenocarcinomaDiagnostic Cytopathology, 2005
- Use of Liquid-Based Cytology in Serous FluidsActa Cytologica, 2004
- Cytologic detection of malignancy in pleural effusion: A review of 5,255 samples from 3,811 patientsDiagnostic Cytopathology, 1987