Assessment of culturable airborne bacteria of indoor environments in classrooms, dormitories and dining hall at university: a case study in China
- 2 March 2020
- journal article
- research article
- Published by Springer Nature in Aerobiologia
- Vol. 36 (3) , 313-324
Abstract
University students’ health may be adversely affected by exposure to indoor bacterial contaminants on their campuses. This study aims (1) to quantify culturable bacterial concentrations in three indoor environments at a university, (2) to investigate the influence of meteorological factors and gender, to assess the relationship between indoor and outdoor, and (3) to estimate the bacterial dose for university students in different indoor environments. Airborne bacteria samples were collected in 12 classrooms, in 12 living rooms and four bathrooms in two dormitory buildings, and in a dining hall. The results showed that the microenvironment in the female dormitory had the highest mean bacterial concentration (2847 CFU/m3), whereas the lowest mean bacterial concentration was observed in classrooms (162 CFU/m3). Indoor bacterial concentrations in male dormitories were significantly lower than in female dormitories probably because of crowding and increased ventilation. Outdoor weather conditions were associated with the indoor concentrations with regard to insufficient ventilation and varying outdoor concentration. The occupants’ activity level was also more closely related to the indoor bacteria concentration in the residential setting. Students experienced about four times higher dose of airborne bacteria in the dormitories than in the classrooms and dining hall.Keywords
Funding Information
- National Natural Science Foundation of China (51308372)
This publication has 42 references indexed in Scilit:
- Human Occupancy as a Source of Indoor Airborne BacteriaPLOS ONE, 2012
- Size‐resolved emission rates of airborne bacteria and fungi in an occupied classroomIndoor Air, 2012
- Airborne bacteria, fungi, and endotoxin levels in residential microenvironments: a case studyAerobiologia, 2011
- Evaluation of microbiological air quality and of microclimate in university classroomsEnvironmental Monitoring and Assessment, 2011
- Respiratory and Allergic Health Effects of Dampness, Mold, and Dampness-Related Agents: A Review of the Epidemiologic EvidenceEnvironmental Health Perspectives, 2011
- Polycyclic aromatic hydrocarbons in gas and particulate phases of indoor environments influenced by tobacco smoke: Levels, phase distributions, and health risksAtmospheric Environment, 2011
- Indoor air quality in university environmentsEnvironmental Monitoring and Assessment, 2009
- Survey of Airborne Bacterial Genus at a University CampusIndoor and Built Environment, 2008
- Assessment of Bioaerosols in the Public Buildings of KoreaIndoor and Built Environment, 2007
- The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutantsJournal of Exposure Science & Environmental Epidemiology, 2001