Evaluation of Four Different Systems for Extraction of RNA from Stool Suspensions Using MS-2 Coliphage as an Exogenous Control for RT-PCR Inhibition
Open Access
- 16 July 2012
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (7) , e39455
Abstract
Knowing when, and to what extent co-extracted inhibitors interfere with molecular RNA diagnostic assays is of utmost importance. The QIAamp Viral RNA Mini Kit (A); MagNA Pure LC2.0 Automatic extractor (B); KingFisher (C); and NucliSENS EasyMag (D) RNA extraction systems were evaluated for extraction efficiency and co-purification of inhibitors from stool suspensions. Real-Time Reverse Transcriptase Polymerase Chain Reaction (rRT-PCR) of MS-2 coliphage spiked into each system’s lysis buffer served as an external control for both. Cycle thresholds (Cts) of the MS2 were determined for RNA extracted from stool suspensions containing unknown (n = 93) or varying amounts of inhibitors (n = 92). Stool suspensions from the latter group were also used to determine whether MS-2 and enterovirus rRT-PCR inhibitions were correlated. Specifically 23 RNA extracts from stool suspensions were spiked with enterovirus RNA after extraction and 13 of these stool suspension were spiked with intact enterovirus before extraction. MS2 rRT-PCR inhibition varied for RNAs extracted by the different systems. Inhibition was noted in 12 (13.0%), 26 (28.3%), 7 (7.6%), and 7 (7.6%) of the first 93 RNA extracts, and 58 (63.0%), 55 (59.8%), 37 (40.2%) and 30 (32.6%) of the second 92 extracts for A, B, C, and D, respectively. Furthermore, enterovirus rRT-PCR inhibition correlated with MS2 rRT-PCR inhibition for added enterovirus RNA or virus particles. In conclusion, rRT-PCR for MS-2 RNA is a good predictor of inhibition of enterovirus RNA extracted from stool suspensions. EasyMag performed the best, however all four extraction methods were suitable provided that external controls identified problematic samples.Keywords
This publication has 28 references indexed in Scilit:
- Validation of Internal Controls for Extraction and Amplification of Nucleic Acids from Enteric Viruses in Water SamplesApplied and Environmental Microbiology, 2011
- RNA and DNA Bacteriophages as Molecular Diagnosis Controls in Clinical Virology: A Comprehensive Study of More than 45,000 Routine PCR TestsPLOS ONE, 2011
- Validation of Laboratory-Developed Molecular Assays for Infectious DiseasesClinical Microbiology Reviews, 2010
- Duplex Real-Time Reverse Transcriptase PCR Assays for Rapid Detection and Identification of Pandemic (H1N1) 2009 and Seasonal Influenza A/H1, A/H3, and B VirusesJournal of Clinical Microbiology, 2010
- Comparison of the NucliSens easyMAG and Qiagen BioRobot 9604 Nucleic Acid Extraction Systems for Detection of RNA and DNA Respiratory Viruses in Nasopharyngeal Aspirate SamplesJournal of Clinical Microbiology, 2008
- Clinical Evaluation of NucliSENS Magnetic Extraction and NucliSENS Analyte-Specific Reagents for Real-Time Detection of Human Metapneumovirus in Pediatric Respiratory SpecimensJournal of Clinical Microbiology, 2008
- Evaluation of NucliSens easyMAG for Automated Nucleic Acid Extraction from Various Clinical SpecimensJournal of Clinical Microbiology, 2007
- Preparation of His-Tagged Armored RNA Phage Particles as a Control for Real-Time Reverse Transcription-PCR Detection of Severe Acute Respiratory Syndrome CoronavirusJournal of Clinical Microbiology, 2006
- Multicenter Comparison of Nucleic Acid Extraction Methods for Detection of Severe Acute Respiratory Syndrome Coronavirus RNA in Stool SpecimensJournal of Clinical Microbiology, 2006
- Rapid One-Step Quantitative Reverse Transcriptase PCR Assay with Competitive Internal Positive Control for Detection of Enteroviruses in Environmental SamplesApplied and Environmental Microbiology, 2006