A Comprehensive Characterization of the TI-LGAD Technology
Open Access
Abstract
Pixelated low-gain avalanche diodes (LGADs) can provide both precision spatial and temporal measurements for charged particle detection; however, electrical termination between the pixels yields a no-gain region, such that the active area or fill factor is not sufficient for small pixel sizes. Trench-isolated LGADs (TI-LGADs) are a strong candidate for solving the fill-factor problem, as the p-stop termination structure is replaced by isolated trenches etched in the silicon itself. In the TI-LGAD process, the p-stop termination structure, typical of LGADs, is replaced by isolating trenches etched in the silicon itself. This modification substantially reduces the size of the no-gain region, thus enabling the implementation of small pixels with an adequate fill factor value. In this article, a systematic characterization of the TI-RD50 production, the first of its kind entirely dedicated to the TI-LGAD technology, is presented. Designs are ranked according to their measured inter-pixel distance, and the time resolution is compared against the regular LGAD technology.Keywords
Funding Information
- European Union’s Horizon 2020 Research and Innovation Program (101004761)
This publication has 15 references indexed in Scilit:
- Resistive AC-Coupled Silicon Detectors: Principles of operation and first results from a combined analysis of beam test and laser dataNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2021
- Novel strategies for fine-segmented Low Gain Avalanche DiodesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2021
- Particle Detectors2020
- Trench-Isolated Low Gain Avalanche Diodes (TI-LGADs)IEEE Electron Device Letters, 2020
- Inverse Low Gain Avalanche Detectors (iLGADs) for precise tracking and timing applicationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2020
- Precision timing detectors with cadmium-telluride sensorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2017
- Test beam studies of silicon timing for use in calorimetryNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Technology developments and first measurements of Low Gain Avalanche Detectors (LGAD) for high energy physics applicationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Development of a new fast shower maximum detector based on microchannel plates photomultipliers (MCP-PMT) as an active elementNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Development of a 10ps level time of flight system in the Fermilab Test Beam FacilityNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010