The use of nonbaffled vessels for mixing applications is becoming common in the biopharmaceutical industry but is not sufficiently well studied. Orientation of the impellers off-centered and/or at an angle is necessary to enhance mixing and eliminate swirling that would result without a baffle in a standard tank. This study focuses on characterizing mixing in vessels with the hydrofoil axial flow impellers mounted off-center at 10 degrees to the vertical. Geometrically similar vessels ranging from 100 to 5000 L working volume were used in this study. Mixing performance was successfully correlated to vessel geometric factors.