The Effects of Exterior Glazing on Human Thermal Comfort in Office Buildings
Open Access
Abstract
As a major component of the building envelope, the energy-saving design of exterior windows is key to energy savings in office buildings. The conventional design of exterior windows mainly focused on their impact on heating and cooling energy but ignored the indoor thermal comfort problems caused by the direct solar radiation transmitted by windows and the fluctuation of their internal surface temperatures. This study analyzed the influence of exterior windows on the indoor thermal environment of office buildings by carrying out field experiments. The experiments were carried out in a typical office building in Xi’an during December and January. The impact of exterior windows on human thermal comfort was studied from two perspectives: longwave radiation from the surface of window glass and solar shortwave radiation. It was found that solar radiation was the main cause of temperature fluctuations on the internal surface of windows and created non-uniform thermal environments. The mean radiant temperature fluctuations in the near-window area could reach up to 7.8 °C due to outdoor solar radiation in winter. Solar radiation transmitted by windows directly affects thermal sensations. Since conventional thermal comfort models or indices underestimated the thermal sensations of occupants in the presence of solar radiation, the additional thermal loads caused by solar radiation needed to be taken into account. The allowable operative temperature range for maintaining thermal comfort should be reduced by 0.5 °C when occupants are exposed to solar radiation.Keywords
Funding Information
- National Natural Science Foundation of China (52108093)
This publication has 30 references indexed in Scilit:
- Native influences on the construction of thermal sensation scalesInternational Journal of Biometeorology, 2020
- Effect of installing a venetian blind to a glass window on human thermal comfortBuilding and Environment, 2014
- Building façade design for daylighting quality in typical government office buildingBuilding and Environment, 2012
- Indoor thermal environmental conditions near glazed facades with shading devices – Part II: Thermal comfort simulation and impact of glazing and shading propertiesBuilding and Environment, 2010
- Indoor thermal environmental conditions near glazed facades with shading devices – Part I: Experiments and building thermal modelBuilding and Environment, 2010
- Relationship between thermal sensation and comfort in non-uniform and dynamic environmentsBuilding and Environment, 2009
- Different glazing systems and their impact on human thermal comfort—Indian scenarioBuilding and Environment, 2008
- The calculation of the mean radiant temperature of a subject exposed to the solar radiation—a generalised algorithmBuilding and Environment, 2005
- Experimental investigation of cold draft induced by two different types of glazing panels in metal curtain wallsBuilding and Environment, 2004