Abstract
Background: In recent years, artificial intelligence (AI) methods, including deep convolutional neural networks (CNNs), have gained increasing importance in supporting the automated analysis of echocardiograms. The aim of this study was to evaluate the impact of selected image artifacts—motion blur, acoustic shadowing, and speckle noise—on the performance of automatic classification of standard transthoracic echocardiographic (TTE) views using deep learning models. Methods: The analysis included 217 TTE video clips (2170 frames) covering apical views: two-chamber (A2C), three-chamber (A3C), four-chamber (A4C), and five-chamber (A5C). Two convolutional neural network architectures—ResNet-18 and ResNet-34—were applied, initialized with weights pretrained on the ImageNet dataset (transfer learning). In a limited comparative scope, EfficientNet-B0, a ViT model used as a frozen feature extractor combined with Logistic Regression, and a classical HOG + SVM model, were also included as reference methods. Classification performance was evaluated under conditions of controlled image degradation caused by motion blur, acoustic shadowing, and speckle noise. Results: All analyzed artifacts reduced classification performance, although the magnitude of this effect depended on artifact type. Speckle noise proved to be the most destructive, causing performance collapse across all evaluated methods at high severity. Motion blur and acoustic shadowing produced more differentiated degradation profiles. The ResNet models achieved the highest performance under reference conditions; however, after degradation, the ranking of models was no longer stable. In the comparative analysis, HOG + SVM showed the smallest relative performance loss under motion blur and the highest balanced accuracy under severe acoustic shadowing, whereas severe speckle remained critical for all models. Conclusions: Image quality degradation significantly impairs TTE view classification performance, and evaluation based solely on reference-quality images does not fully reflect model robustness to artifacts. These findings indicate the need to complement standard model evaluation with a structured robustness analysis under degraded imaging conditions and highlight the importance of training and validation settings that better reflect real clinical practice.Keywords
Funding Information
- “Doktorat Wdrożeniowy 2023” Program
- “Umowa o współpracy w zakresie prowadzenia doktoratu wdrożeniowego” (PCTT/2541/2023)
This publication has 51 references indexed in Scilit:
- Systematic Review of Hybrid Vision Transformer Architectures for Radiological Image AnalysisJournal of Imaging Informatics in Medicine, 2025
- Comparison of Vision Transformers and Convolutional Neural Networks in Medical Image Analysis: A Systematic ReviewJournal of Medical Systems, 2024
- Holographic mixed reality for planning transcatheter aortic valve replacementInternational Journal of Cardiology, 2024
- A survey of the vision transformers and their CNN-transformer based variantsArtificial Intelligence Review, 2023
- Real-time echocardiography image analysis and quantification of cardiac indicesMedical Image Analysis, 2022
- Artificial Intelligence Aids Cardiac Image Quality Assessment for Improving Precision in Strain MeasurementsJACC: Cardiovascular Imaging, 2021
- Guidelines for Performing a Comprehensive Transthoracic Echocardiographic Examination in Adults: Recommendations from the American Society of EchocardiographyJournal of the American Society of Echocardiography, 2019
- Speckle noise removal in ultrasound images by first- and second-order total variationNumerical Algorithms, 2017
- Automatic apical view classification of echocardiograms using a discriminative learning dictionaryMedical Image Analysis, 2017
- Fact or Artifact in Two-Dimensional Echocardiography: Avoiding Misdiagnosis and Missed DiagnosisJournal of the American Society of Echocardiography, 2016