Experimental Comparison of Fiducial Markers Used in Proton Therapy: Study of Different Imaging Modalities and Proton Fluence Perturbations Measured With CMOS Pixel Sensors
Authors:
Open Access
- 25 March 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 12, 830080
Abstract
Fiducial markers are used for image guidance to verify the correct positioning of the target for the case of tumors that can suffer interfractional motion during proton therapy. The markers should be visible on daily imaging, but at the same time, they should produce minimal streak artifacts in the CT scans for treatment planning and induce only slight dose perturbations during particle therapy. In this work, these three criteria were experimentally investigated at the Heidelberg Ion Beam Therapy Center. Several small fiducial markers with different geometries and materials (gold, platinum, and carbon-coated ZrO2) were evaluated. The streak artifacts on treatment planning CT were measured with and without iMAR correction, showing significantly smaller artifacts from markers lighter than 6 mg and a clear improvement with iMAR correction. Daily imaging as X-ray projections and in-room mobile CT were also performed. Markers heavier than 6 mg showed a better contrast in the X-ray projections, whereas on the images from the in-room mobile CT, all markers were clearly visible. In the other part of this work, fluence perturbations of proton beams were measured for the same markers by using a tracker system of several high spatial resolution CMOS pixel sensors. The measurements were performed for single-energy beams, as well as for a spread-out Bragg peak. Three-dimensional fluence distributions were computed after reconstructing all particle trajectories. These measurements clearly showed that the ZrO2 markers and the low-mass gold/platinum markers (0.35mm diameter) induce perturbations being 2–3 times lower than the heavier gold or platinum markers of 0.5mm diameter. Monte Carlo simulations, using the FLUKA code, were used to compute dose distributions and showed good agreement with the experimental data after adjusting the phase space of the simulated proton beam compared to the experimental beam.Keywords
This publication has 37 references indexed in Scilit:
- Evaluation of different fiducial markers for image-guided radiotherapy and particle therapyJournal of Radiation Research, 2013
- Biological effect of dose distortion by fiducial markers in spot‐scanning proton therapy with a limited number of fields: A simulation studyMedical Physics, 2012
- Investigation of dose perturbations and the radiographic visibility of potential fiducials for proton radiation therapy of the prostatePhysics in Medicine & Biology, 2011
- Dose perturbations and image artifacts caused by carbon-coated ceramic and stainless steel fiducials used in proton therapy for prostate cancerPhysics in Medicine & Biology, 2010
- Investigation of the dosimetric impact of a Ni-Ti fiducial marker in carbon ion and proton beamsActa Oncologica, 2010
- Dose perturbations from implanted helical gold markers in proton therapy of prostate cancerJournal of Applied Clinical Medical Physics, 2009
- Dosimetric impact of tantalum markers used in the treatment of uveal melanoma with proton beam therapyPhysics in Medicine & Biology, 2007
- Monte Carlo simulations of the dosimetric impact of radiopaque fiducial markers for proton radiotherapy of the prostatePhysics in Medicine & Biology, 2007
- ErratumNuclear Instruments and Methods, 1979
- Some practical remarks on multiple scatteringNuclear Instruments and Methods, 1975