Hip capsular strain varies between ligaments dependent on both hip position- and applied rotational force
Authors:
- 3 May 2020
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 28 (10) , 3393-3399
Abstract
Purpose To noninvasively characterize the ligament strain in the hip capsule using a novel CT-based imaging technique. Methods The superior iliofemoral ligament (SIFL), inferior iliofemoral ligament (IIFL), ischiofemoral ligament (IFL) and pubofemoral ligament (PFL) were identified and beaded in seven cadavers. Specimens were mounted on a joint motion simulator within an O-arm CT scanner in − 15°, 0°, 30°, 60°, and 90° of flexion. 3 Nm of internal rotation (IR) and external rotation (ER) were applied and CT scans obtained. Strains were calculated by comparing bead separation in loaded and unloaded conditions. Repeated-measures ANOVA was used to evaluate differences in strain within ligaments between hip positions. Results For the SIFL, strain significantly decreased in IR at 30° (p = 0.045) and 60° (p = 0.043) versus 0°. For ER, there were no significant position-specific changes in strain (n.s.). For the IIFL, strain decreased in IR and increased in ER with no significant position-specific differences. For the IFL, strain increased with IR and decreased with ER with no significant position-specific differences. Finally, in the PFL there was a significant flexion angle-by-load interaction (p < 0.001; ES = 0.566), with peak strains noted at 60˚, however pair-wise comparisons failed to identify significant differences between positions (n.s.). Strain decreased in ER, with no significant position-specific differences. Conclusion The SIFL and IIFL limit hip external rotation with greater effect in higher flexion angles, while the IFL and PFL limit hip internal rotation. Following hip arthroscopy, consideration should be given to restricting external rotation as traditional capsulotomies cause injury to the SIFL and IIFL.Keywords
Funding Information
- Academic Medical Organization of Southwestern Ontario (#F17-004)
- Smith and Nephew Orthopaedics (A17-ASDUS-GR-598)
This publication has 23 references indexed in Scilit:
- Capsulotomy Size Affects Hip Joint Kinematic StabilityArthroscopy, 2016
- Capsular Management in Hip Arthroscopy: An Anatomic, Biomechanical, and Technical ReviewFrontiers in Surgery, 2016
- Biomechanical Evaluation of Capsulotomy, Capsulectomy, and Capsular Repair on Hip RotationArthroscopy, 2015
- Ligament strain on the iliofemoral, pubofemoral, and ischiofemoral ligaments in cadaver specimens: Biomechanical measurement and anatomical observationClinical Anatomy, 2014
- Capsular Management During Hip Arthroscopy: From Femoroacetabular Impingement to InstabilityArthroscopy, 2011
- Role of the Acetabular Labrum and the Iliofemoral Ligament in Hip StabilityThe American Journal of Sports Medicine, 2011
- The Function of the Hip Capsular Ligaments: A Quantitative ReportArthroscopy, 2007
- Metal artifact reduction in CT using tissue-class modeling and adaptive prefilteringMedical Physics, 2006