Design and Experimental Verification of a 50 kW Interior Permanent Magnet Synchronous Machine
Authors:
- 1 October 2006
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4, 1941-1948
Abstract
This paper presents the design details for an IPM machine designed to deliver 50 kW constant power over a 5:1 speed range extending from 850 rpm to 4250 rpm, with a gradual reduction in the required output power up to 8000 rpm (25 kW). Electromagnetic, thermal, and structural considerations have been included in the design optimization process. The resulting machine is designed with two magnet layers per pole and a distributed stator winding. Special features of the machine include its deep stator slots and four-layer winding, made necessary by the desire to minimize the machine's moment of inertia. Test results available to date demonstrate that the machine is capable of delivering the required output torque and power, and the agreement between the predicted and measured machine parameters is generally quite good. Calculated iron losses for high-speed flux-weakening operation are presented in the final section of the paper, illustrating the challenges associated with minimizing the impact of high-frequency harmonic flux density componentsKeywords
This publication has 7 references indexed in Scilit:
- Impact of Maximum Back-EMF Limits on the Performance Characteristics of Interior Permanent Magnet Synchronous Machines2006
- Iron loss reduction in an interior PM automotive alternator2005
- Iron loss analysis of interior permanent magnet synchronous motors variation of main loss factors due to driving condition2005
- Iron losses in salient permanent magnet machines at field-weakening operation2004
- Magnetic models of saturated interior permanent magnet motors based on finite element analysis2002
- A saturating lumped-parameter model for an interior PM synchronous machineIEEE Transactions on Industry Applications, 2002
- Expansion of operating limits for permanent magnet motor by current vector control considering inverter capacityIEEE Transactions on Industry Applications, 1990