Adjustment of Open-Loop Settings to Improve Closed-Loop Results in Type 1 Diabetes: A Multicenter Randomized Trial
Open Access
- 1 October 2015
- journal article
- research article
- Published by The Endocrine Society in The Journal of Clinical Endocrinology & Metabolism
- Vol. 100 (10) , 3878-3886
Abstract
Context: Closed-loop control (CLC) relies on an individual's open-loop insulin pump settings to initialize the system. Optimizing open-loop settings before using CLC usually requires significant time and effort. Objective: The objective was to investigate the effects of a one-time algorithmic adjustment of basal rate and insulin to carbohydrate ratio open-loop settings on the performance of CLC. Design: This study reports a multicenter, outpatient, randomized, crossover clinical trial. Patients: Thirty-seven adults with type 1 diabetes were enrolled at three clinical sites. Interventions: Each subject's insulin pump settings were subject to a one-time algorithmic adjustment based on 1 week of open-loop (i.e., home care) data collection. Subjects then underwent two 27-hour periods of CLC in random order with either unchanged (control) or algorithmic adjusted basal rate and carbohydrate ratio settings (adjusted) used to initialize the zone-model predictive control artificial pancreas controller. Subject's followed their usual meal-plan and had an unannounced exercise session. Main Outcomes and Measures: Time in the glucose range was 80–140 mg/dL, compared between both arms. Results: Thirty-two subjects completed the protocol. Median time in CLC was 25.3 hours. The median time in the 80–140 mg/dl range was similar in both groups (39.7% control, 44.2% adjusted). Subjects in both arms of CLC showed minimal time spent less than 70 mg/dl (median 1.34% and 1.37%, respectively). There were no significant differences more than 140 mg/dL. Conclusions: A one-time algorithmic adjustment of open-loop settings did not alter glucose control in a relatively short duration outpatient closed-loop study. The CLC system proved very robust and adaptable, with minimal (<2%) time spent in the hypoglycemic range in either arm.Keywords
This publication has 26 references indexed in Scilit:
- Clinical Evaluation of an Automated Artificial Pancreas Using Zone-Model Predictive Control and Health Monitoring SystemDiabetes Technology & Therapeutics, 2014
- Multivariable Adaptive Identification and Control for Artificial Pancreas SystemsIEEE Transactions on Biomedical Engineering, 2014
- Use of a “Fuzzy Logic” Controller in a Closed-Loop Artificial PancreasDiabetes Technology & Therapeutics, 2013
- Diurnal Pattern of Insulin Action in Type 1 DiabetesDiabetes, 2013
- Clinical Evaluation of a Personalized Artificial PancreasDiabetes Care, 2013
- Effect of Automated Bio-Behavioral Feedback on the Control of Type 1 DiabetesDiabetes Care, 2011
- Modular Artificial β-Cell System: A Prototype for Clinical ResearchJournal of Diabetes Science and Technology, 2008
- Risk Analysis of Blood Glucose Data: A Quantitative Approach to Optimizing the Control of Insulin Dependent DiabetesComputational and Mathematical Methods in Medicine, 2000
- Reduction to Normal of Plasma Glucose in Juvenile Diabetes by Subcutaneous Administration of Insulin with a Portable Infusion PumpNew England Journal of Medicine, 1979
- Continuous subcutaneous insulin infusion: an approach to achieving normoglycaemia.BMJ, 1978