Achieving functional alignment in total knee arthroplasty: early experience using a second-generation imageless semi-autonomous handheld robotic sculpting system
- 12 December 2022
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 47 (2) , 585-593
Abstract
Purpose In order to minimize errors during achieving the targeted alignment of the total knee arthroplasty (TKA) components, robotic-assisted surgery has been introduced with the aim to help surgeons to improve implant survival, clinical outcomes, and patient satisfaction. The primary goal of this paper is to highlight surgical tips and tricks on how to achieve functional alignment (FA) through intra-operative boney mapping, numeric gap, and alignment data, using the next generation of imageless robotic surgical systems. Method This retrospective case-series contains planned and achieved data on the FA and joint gap data obtained from 526 patients captured and assessed with use of a semi-autonomous imageless handheld robotic sculpting systems. All patients were operated upon by two experienced TKA surgeons. Results The mean difference between planned and achieved alignment was 1.46° (≥ 7° varus group), 1.02° (< 7° varus group), 1.16° (< 7° valgus group), and 1.43° (≥ 7° valgus group). The mean observed planned and achieved extension and flexion gaps were below 1.47 mm for medial extension gaps, 1.12 mm for the lateral extension gaps, 1.4 mm for the medial flexion gaps, and 1.16 mm for the lateral flexion gaps. Conclusion Analysis of these first cases highlights the capability of the next generation of imageless robotic-assisted total knee replacement using a semi-autonomous handheld robotic sculpting to maintain accuracy of the desired alignment. The system allows the surgeon to choose freely their own alignment philosophy while maintaining efficiency.Keywords
This publication has 33 references indexed in Scilit:
- Noise Exposure in TKA Surgery; Oscillating Tip Saw Systems vs Oscillating Blade Saw SystemsThe Journal of Arthroplasty, 2016
- Early experiences with robot-assisted total knee arthroplasty using the DigiMatch™ ROBODOC® surgical systemSingapore Medical Journal, 2014
- Increased satisfaction after total knee replacement using sensor-guided technologyThe Bone & Joint Journal, 2014
- Mechanical, Anatomical, and Kinematic Axis in TKA: Concepts and Practical ApplicationsCurrent Reviews in Musculoskeletal Medicine, 2014
- Coronal Alignment Correlates With Outcome After Total Knee ArthroplastyThe Journal of Arthroplasty, 2012
- Coronal Alignment in Total Knee ArthroplastyThe Journal of Arthroplasty, 2009
- Correlation between radiographic assessment and quality of life after total knee arthroplastyThe Knee, 2009
- Good Alignment After Total Knee Arthroplasty Leads to Faster Rehabilitation and Better FunctionThe Journal of Arthroplasty, 2009
- The total condylar knee prosthesis. A report of two hundred and twenty cases.Journal of Bone and Joint Surgery, 1979
- Influence of positioning of prosthesis in total knee replacementJournal of Bone and Joint Surgery, 1977