Tandem mass spectrometry is a powerful technique for investigating polymer architecture. However, in‐depth studies of the technique for polymers is relatively lacking when compared to other areas of mass spectrometry (MS). This paper examines the use laser‐induced dissociation and collision‐induced dissociation (CID) in MALDI–LIFT–ToF/ToF experiments to compare the usage of the two techniques on a range of polymeric analytes. It is demonstrated that for samples with an energetically preferable fragmentation pathway, such as those with a functional group in the backbone or a labile end group, post source decay (PSD) provides a simplified spectra with an increased pathway selectivity due to its utilization of metastable decay. This makes PSD a preferable technique for polymer sequencing, especially in low‐resolution time‐of‐flight techniques. Conversely, CID fragments less selectively, leading to higher intensity peaks from less favorable fragmentations. This makes CID more preferred for exact structural determination, such as finding the repeat unit structure.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/L015307/1)
- Syngenta International
- AstraZeneca
This publication has 27 references indexed in Scilit:
- MALDI-LID-ToF/ToF analysis of statistical and diblock polyacrylate copolymersPolymer Chemistry, 2018
- Oxidative polymerization of catecholamines: structural access by high-resolution mass spectrometryPolymer Chemistry, 2017
- Sequence-coded ATRP macroinitiatorsPolymer Chemistry, 2017
- MS/MS-Assisted Design of Sequence-Controlled Synthetic Polymers for Improved Reading of Encoded InformationJournal of the American Society for Mass Spectrometry, 2016
- Sequence Analysis of Styrenic Copolymers by Tandem Mass SpectrometryAnalytical Chemistry, 2014
- Systematic MALDI‐TOF CID Investigation on Different Substituted mPEG 2000Macromolecular Chemistry and Physics, 2010
- Sequence determination in aliphatic poly(ester amide)s by matrix‐assisted laser desorption/ionization time‐of‐flight and time‐of‐flight/time‐of‐flight tandem mass spectrometryRapid Communications in Mass Spectrometry, 2005
- Microstructural and conformational studies of polyether copolymersInternational Journal of Mass Spectrometry, 2004
- Structural Analysis of Polymer End Groups by Electrospray Ionization High-Energy Collision-Induced Dissociation Tandem Mass SpectrometryAnalytical Chemistry, 2000
- Determination of End Groups of Synthetic Polymers by Matrix-Assisted Laser Desorption/Ionization: High-Energy Collision-Induced DissociationAnalytical Chemistry, 1999