Abstract
Nowadays, thermal inner comfort has become a prerogative either for inhabitants, workers, or even casual users of any type of buildings. Simultaneously, current historic juncture has converted energy saving and CO2 emissions reduction into a must. Particularly, when it comes to patrimonial constructions in use, both objectives are to be achieved complying with the legal framework that ensures future preservation. The aim of this work is to quantify eventual energy savings in an Asturian historical residence (the Busquets House), when comfort heating requirements are cut down. To do so, comfort condition has been established according to Dear and Brager (1) adaptative model and reductions have been set according to lower 80% and 90% acceptable limits. A transient regime simulation of the house thermal behavior was also developed. Therein, former conditions were integrated as inputs and final heating energy demand was obtained as an output. Simulation results revealed that, in a regular use scenario, 100% acceptability requires 12.317 MWh/year, 90% acceptability needs 8.183 MWh/year, and 80% acceptability demands 6.830 MWh/year. In other words, if criteria of 20% most cold-sensitive people were not to be considered, heating expenditure at the Busquets House could be reduced by 46.29%.

This publication has 13 references indexed in Scilit: