Effect of Different Methods of Blood Decontamination on Resin-Resin Micro-Shear Bond Strength
Authors:
- Zahra Jaberi AnsariZAZahra Jaberi Ansari
- Haleh Valizadeh HaghiHHHaleh Valizadeh Haghi
Open Access
- 30 June 2017
- journal article
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. 9 (3) , e60711
Abstract
Background: Blood contamination could interfere with the bonding of resin materials to different substrates. Objectives: The purpose of this study was to evaluate the effects of various methods of removing blood contamination between composite resin increments on resin-resin micro-shear bond strength. Methods: 90 composite blocks (Valux Plus, 3M ESPE) measuring 2 × 2 × 8 mm were prepared in 6 groups: one group was not contaminated as the control (group 1); for other groups the surface was contaminated with blood then rinsed and dried. One group only received this treatment (group 2) and others were etched with phosphoric acid (group 3), phosphoric acid and a bonding agent (Margin Bond, Coltene) (group 4), cleaned with 98% ethanol (group 5), and had 0.5 mm of their outer surface removed (group 6). Next, the second increments of composite were applied in the form of cylinders of 0.7 mm diameter and 1 mm height on the top surfaces of the specimens and were then light cured. Specimens underwent micro-shear bond strength testing. Data were analyzed by Kolmogorov-Smirnov and analysis of variance (ANOVA) tests. Results: The mean value of bond strength was 23 ± 3.60 MPa for the control group, 17.89 ± 6.52 MPa for group 2, 19.40 ± 6.08 MPa for group 3, 20.20 ± 5.72 MPa for group 4, 20.01 ± 6.83 MPa for group 5, and 19.10 ± 6.20 MPa for group 6. There were no significant differences between the groups. Conclusions: All the decontamination methods in this study could increase the resin-resin bond strength to the level of the control group. Keywords: Blood Contamination; Decontamination Method; Resin-Resin Micro-Shear Bond StrengthKeywords
This publication has 11 references indexed in Scilit:
- Influence of Blood Contamination on Bond Strength of a Self-etching Adhesive to Dental Tissues2011
- Influence of decontamination procedures on shear forces after contamination with blood or salivaAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2010
- Influence of Blood Contamination on Bond Strength of a Self-Etching SystemEuropean Journal of Dentistry, 2010
- An in vitro comparative assessment of different enamel contaminants during bracket bondingEuropean Journal of Orthodontics, 2007
- Effect of blood and saliva contamination on bond strength of brackets bonded with a protective liquid polish and a light-cured adhesiveAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2007
- Effect of Blood Contamination with 1-step Self-etching Adhesives on Microtensile Bond Strength to DentinOperative Dentistry, 2006
- Effects of saliva contamination on resin–resin bond strengthDental Materials, 2004
- A comparison of microtensile bond strengths of several dentin bonding systems to primary and permanent dentinDental Materials, 2002
- In vitro bond strength of two adhesives to enamel and dentin under normal and contaminated conditionsDental Materials, 1993
- Oral fluid contamination of etched enamel surfaces: an SEM studyThe Journal of the American Dental Association, 1985