Abstract
Background: The serum-free immunoglobulin light chain assay has been recommended as a screening test for monoclonal gammopathy. We evaluated the usefulness of urine free immunoglobulin light concentration for selection of specimens for immunofixation electrophoresis. Methods: Using kits from The Binding Site for Freelite ®, we validated examination of urine for measuring free κ and λ light chains. The results of urine free light chain concentrations were evaluated to ascertain if the results could be used to reduce the number of specimens requiring urine protein immunofixation electrophoresis. Results: In the 515 specimens examined, there was no evidence of monoclonal gammopathy or history of monoclonal gammopathy in 331. Monoclonal κ or λ light chains were detectable in 42 and 30 specimens, respectively. There was history of κ or λ chain associated monoclonal gammopathy in 62 and 50 patients, respectively. In the 38 monoclonal κ positive urine specimens, with light chain data, κ/λ ratio was >5.83 in all specimens. In 27 specimens positive for monoclonal λ light chains, with light chain data, the urine λ/κ ratio was > 0.17 in 24 of 27 specimens and > 0.041 in all specimens. In patients without monoclonal gammopathy all specimens had a κ/λ ratio of >5.83 or λ/κ ratio >0.17. Conclusions: The Freelite ® assay from The Binding Site is suitable for quantification of free light chains in urine. In patients with known history of monoclonal gammopathy, urine immunofixation electrophoresis may be omitted in specimens with κ/λ ratio of <5.83 for κ associated lesions and λ/κ ratio of <0.041 for λ associated lesions. However, the results do not support using this test for first-time urine testing for monoclonal light chains as it is not predictive of positive result, nor does it exclude a monoclonal light chain in urine.Keywords
This publication has 24 references indexed in Scilit:
- Serum Free Light Chain Assay and κ/λ Ratio: Performance in Patients With Monoclonal Gammopathy-High False Negative Rate for κ/λ RatioJournal of Clinical Medicine Research, 2017
- Serum free light chains, not urine specimens, should be used to evaluate response in light-chain multiple myelomaBlood, 2016
- Serum Free Light Chain Assay and κ/λ Ratio Performance in Patients Without Monoclonal GammopathiesAmerican Journal of Clinical Pathology, 2016
- International Myeloma Working Group updated criteria for the diagnosis of multiple myelomaThe Lancet Oncology, 2014
- IgG Subclasses and Allotypes: From Structure to Effector FunctionsFrontiers in Immunology, 2014
- Receiver Operating Characteristic Curve in Diagnostic Test AssessmentJournal of Thoracic Oncology, 2010
- Structure and function of immunoglobulinsJournal of Allergy and Clinical Immunology, 2010
- Quantification of Urinary Light ChainsClinical Chemistry, 2008
- Elimination of the Need for Urine Studies in the Screening Algorithm for Monoclonal Gammopathies by Using Serum Immunofixation and Free Light Chain AssaysMayo Clinic Proceedings, 2006
- Index for rating diagnostic testsCancer, 1950