Electrochemical Sensor for Bilirubin Detection Using Screen Printed Electrodes Functionalized with Carbon Nanotubes and Graphene
Open Access
Abstract
Practice oriented point-of-care diagnostics require easy-to-handle, miniaturized, and low-cost analytical tools. In a novel approach, screen printed carbon electrodes (SPEs), which were functionalized with nanomaterials, are employed for selective measurements of bilirubin, which is an important biomarker for jaundice. Multi-walled carbon nanotubes (MWCNT) and graphene separately deposited on SPEs provide the core of an electrochemical sensor for bilirubin. The electrocatalytic activity towards bilirubin oxidation (bilirubin to biliverdin) was observed at +0.25 V. In addition, a further peak corresponding to the electrochemical conversion of biliverdin into purpurin appeared at +0.48 V. When compared to MWCNT, the graphene type shows a 3-fold lower detection limit (0.3 ± 0.022 nM and 0.1 ± 0.018 nM, respectively), moreover, the graphene type exhibits a larger linear range (0.1–600 µM) than MWCNT (0.5–500 µM) with a two-fold better sensitivity, i.e., 30 nA µM−1 cm−2, and 15 nA µM−1 cm−2, respectively. The viability is validated through measurements of bilirubin in blood serum samples and the selectivity is ensured by inhibiting common interfering biological substrates using an ionic nafion membrane. The presented approach enables the design and implementation of low cost and miniaturized electrochemical sensors.Keywords
This publication has 40 references indexed in Scilit:
- Molecularly imprinted hydroxyapatite thin film for bilirubin recognitionBiosensors and Bioelectronics, 2011
- Voltammetric Behavior of Bilirubin Based on [bmim][PF6] As the Supporting Electrolyte in Organic Solvent and Its Analytical ApplicationAmerican Journal of Biomedical Sciences, 2011
- Electrochemistry of redox-active self-assembled monolayersCoordination Chemistry Reviews, 2010
- Electrocatalytic oxidation of bilirubin at ferrocenecarboxamide modified MWCNT–gold nanocomposite electrodesMicrochimica Acta, 2008
- An amperometric bilirubin biosensor based on a conductive poly-terthiophene–Mn(II) complexBiosensors and Bioelectronics, 2008
- A portable potentiostat for the bilirubin-specific sensor prepared from molecular imprintingBiosensors and Bioelectronics, 2007
- Bilirubin metabolism: Applied physiologyCurrent Paediatrics, 2006
- A fiber optic sensor for rapid analysis of bilirubin in serumAnalytica Chimica Acta, 1997
- Enzyme electrode for the determination of bilirubinElectroanalysis, 1996
- Polarographic Investigation and Determination of BilirubinAnalytical Sciences, 1994